Quality assurance of gating response times for surface guided motion management treatment delivery using an electronic portal imaging detector
Related Experiment Video
Updated: Jan 25, 2026

Author Spotlight: Using Hyperpolarized Xenon-129 MRI to Study Lung Diseases
Published on: January 5, 2024
Gary Barfield1,2, Edward William Burton3, Jonathan Stoddart1
1Department of Radiotherapy Physics, United Lincolnshire Hospitals NHS Trust, Lincoln, United Kingdom.
Abstract:
Gating response times of monitoring system/LINAC combinations for gated radiotherapy treatments are notoriously difficult to measure. This difficulty may reflect why the incorporation of gating response times is not thoroughly considered when creating treatment margins for gated radiotherapy treatments, however ignoring the effect of gating response time could lead to significant treatment inaccuracies. This study shows a methodology which measured gating response times for AlignRT/Varian Truebeam combination which appears to be applicable to any surface guided monitoring/Linac combination as well as those combinations which incorporate extended lag times (>200 ms). Beam on lag time appears to be measurably greater than beam off lag time. Although these gating response times are slower than other gating systems on the market, the advantages surface guided radiotherapy (SGRT) could potentially provide for treatment accuracy is discussed as well as demonstrating the lack of guidance regarding SGRT with respect to gated treatments.
More Related Videos
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
04:09Predicting Treatment Response to Image-Guided Therapies Using Machine Learning: An Example for Trans-Arterial Treatment of Hepatocellular Carcinoma
Published on: October 10, 2018
Related Concept Videos
Quality Assurance
Response Surface Methodology
The process of RSM involves several key steps:
Hepatic Portal System
At its core, the hepatic portal vein is the result of a confluence of the superior and inferior mesenteric veins along with the splenic vein. Each of these veins has a unique role. The superior mesenteric vein is...
Applications of GIS: Disaster Management and Emergency Response
Ligand-Gated Ion Channel Receptor: Gating Mechanism
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...