Sanitary Evaluation of Target Flowmeter Used in a Dairy Processing Plant
Annel K Greene1, Thomas G Reynolds2, Emily M Southerland1
1Department of Animal, Dairy and Veterinary Sciences, Clemson University, Clemson, South Carolina 29634.
Abstract:
A target flowmeter, used to measure raw milk flow, was examined for sanitary conditions in a university dairy plant 10 times over a period of eight weeks. The flowmeter connection was swabbed at four different locations along the dairy plant connection at four different times during the work day: i) after chlorine sanitization, before product; ii) after product, before cleaning in place (CIP); iii) after CIP, before acid sanitization; and iv) after acid sanitization, at end of day. Samples were plated in duplicate on standard plate count agar and on violet red bile agar. After routine CIP cleaning and sanitization procedures, bacterial counts were low. Additionally, no finished product contamination problems were detected over the 7 months of flowmeter use as shown by routine quality control tests on pasteurized milk which had flowed past the in-line meter as raw milk. These results indicate that normal cleaning and sanitization procedures were adequate for the in-line flowmeter.
More Related Videos
07:40A Gusseted Thermogradient Table to Control Soil Temperatures for Evaluating Plant Growth and Monitoring Soil Processes
Published on: October 22, 2016
11:47Evaluation of the Efficacy of Organic Peroxyacids for Eradicating Dairy Biofilms Using an Approach Combining Static and Dynamic Methods
Published on: December 9, 2022
Related Concept Videos
Plant Breeding and Biotechnology
Plant Hormones
Tonicity in Plants
Role of Communication in the Nursing Process III: Evaluation and Documentation
Plant Cell Wall
Plant Cells and Tissues