Rapid Method for Detection of Staphylococcus aureus in Feces

Summary

A new method using Fe₃O₄ @SiO₂ microbeads and loop-mediated isothermal amplification (LAMP) rapidly detects low levels of Staphylococcus aureus DNA. This sensitive technique offers a simple, cost-effective tool for diagnosing infections at the point of care.

Related Concept Videos

Feces Formation and Defecation01:26

Feces Formation and Defecation

After spending 3 to 10 hours in the large intestine, chyme loses a lot of water and becomes feces, the final product of digestion. Feces consist of undigested dietary fiber such as cellulose, mucus, sloughed-off epithelial cells, and microbes. The descending and sigmoid colon stores feces and uses haustral contractions to dry it out but retains enough water to give it a semi-solid texture.
The mass peristalsis then pushes the feces into the rectum, which stretches the rectal walls to activate...
3.8K
Effects of EDTA on End-Point Detection Methods01:18

Effects of EDTA on End-Point Detection Methods

Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
634
Precipitation Titration: Endpoint Detection Methods01:19

Precipitation Titration: Endpoint Detection Methods

In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
5.9K
Rapidly Varying Flow01:24

Rapidly Varying Flow

Rapidly varying flow (RVF) in open channels is characterized by abrupt changes in flow depth over a short distance, with the rate of depth change relative to distance often approaching unity. These flows are inherently complex due to their transient and multi-dimensional nature, making exact analysis difficult. However, approximate solutions using simplified models provide valuable insights into their behavior.Key Features of Rapidly Varying FlowRVF is commonly observed in scenarios involving...
467
RACE - Rapid Amplification of cDNA Ends02:35

RACE - Rapid Amplification of cDNA Ends

Rapid Amplification of cDNA Ends, or RACE, is one of the most effective methods to obtain a full-length cDNA from an mRNA sequence between a known internal region to the unknown sequence at the 5’ or 3’ end. The unknown region is cloned in the cDNA by a gene-specific primer that binds the known end, and a hybrid primer that attaches a predefined anchor sequence to the unknown end of the cDNA. The sequence in between is amplified by PCR with an anchor primer and a gene-specific...
7.2K
Detection of Gross Error: The Q Test01:00

Detection of Gross Error: The Q Test

When one or more data points appear far from the rest of the data, there is a need to determine whether they are outliers and whether they should be eliminated from the data set to ensure an accurate representation of the measured value. In many cases, outliers arise from gross errors (or human errors) and do not accurately reflect the underlying phenomenon. In some cases, however, these apparent outliers reflect true phenomenological differences. In these cases, we can use statistical methods...
6.9K