Outcome of complex tibial plateau fractures with Ilizarov external fixation with or without minimal internal fixation
Koushik Narayan Subramanyam1, Madhusudhan Tammanaiah1, Abhishek Vasant Mundargi1
1Department of Orthopaedics, Sri Sathya Sai Institute of Higher Medical Sciences, Prashanthigram, Puttaparthi, Andhra Pradesh 515134, India.
Purpose:
To evaluate the clinico-radiological outcome of complex tibial plateau fractures treated with Ilizarov external fixation with or without minimal internal fixation.
Methods:
This retrospective review was conducted on all the cases of Schatzker types V and VI tibial plateau fractures treated by Ilizarov external fixation between July 2006 and December 2015 with the minimum follow-up duration of one year. There were 30 patients: 24 males and 6 females, mean age 43.33 years, and mean follow-up 3.6 years. Three of them were open fractures; 15 cases were Schatzkertype V fractures and the other 15 type VI. According to AO/OTA classification, there were 11 type C1, 12 C2 and 7 type C3 fractures. Outcome assessment was made with American Knee Society Score (AKSS) and Rasmussen's Radiological Score (RRS) at final follow-up.
Results:
Out of the 30 cases, mini-open reduction was performed in 7, bone graft in 4, minimal internal fixation in 10 and knee temporary immobilisation in 11 patients. Mean duration of external fixation was 11.8 weeks. All fractures united. Pin tract infections in 7 and common peroneal neuropathy in 2 patients were self-limiting. Two patients had axial misalignment of less than 10°. At final follow-up, the mean knee range of motion was 114.7, mean AKSS 81.5 and mean RRS 16.7. On statistical analysis, Schatzker type of fractures, use of minimal internal fixation and knee-spanning did not influence the final outcome.
Conclusion:
Ilizarov external fixator with or without minimal internal fixation provides acceptable outcome for complex tibial plateau fractures. Care must be taken to look for minor loss of alignment, especially in Type VI Schatzker fractures after removal of the fixator. However small sample size precludes firm conclusions.
More Related Videos
Related Concept Videos
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...