Related Experiment Video
Updated: Jan 25, 2026

A Protocol to Set Up Needle-Free Connector with Positive Displacement on Central Venous Catheter in Intensive Care Unit
Published on: July 13, 2019
Embolized Guidewire into Central Aorta: A Nightmare in the Pediatric Intensive Care Unit
R K Nath1, Richa Agrawal1, Manoj Sarowa1
1Department of Cardiology, Ram Manohar Lohia Hospital, New Delhi, Delhi.
Abstract:
A 4-month-old preterm, critically ill infant weighing 3.8 kg was admitted to our pediatric intensive care unit with congestive cardiac failure due to a large ventricular septal defect and its sequelae. During an attempt to insert a central line into the right subclavian vein at bedside, the guidewire inadvertently entered the subclavian artery and embolized distally. After multiple failed retrieval attempts, including surgical femoral cut-down to retrieve the wire, it was removed finally by fluoroscopic-guided percutaneous catheterization with the help of a cardiac bioptome and a gooseneck snare utilizing a novel maneuver.