Evaluation of single-view contrast-enhanced mammography as novel reading strategy: a non-inferiority feasibility
M B I Lobbes1,2, J Hecker3, I P L Houben3
1Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, P.O. Box 5800, 6202 AZ, Maastricht, The Netherlands. marc.lobbes@mumc.nl.
Background:
Guidelines recommend screening of high-risk women using breast magnetic resonance imaging (MRI). Contrast-enhanced mammography (CEM) has matured, providing excellent diagnostic accuracy. To lower total radiation dose, evaluation of single-view (1 V) CEM exams might be considered instead of double-view (2 V) readings as an alternative reading strategy in women who cannot undergo MRI.
Methods:
This retrospective non-inferiority feasibility study evaluates whether the use of 1 V results in an acceptable sensitivity for detecting breast cancer (non-inferiority margin, - 10%). CEM images from May 2013 to December 2017 were included. 1 V readings were performed by consensus opinion of three radiologists, followed by 2 V readings being performed after 6 weeks. Cases were considered "malignant" if the final BI-RADS score was ≥ 4, enabling calculation of sensitivity, specificity, and area under the receiver operating characteristic curve (AUC). Histopathological results or follow-up served as a gold standard.
Results:
A total of 368 cases were evaluated. Mean follow-up for benign or negative cases was 20.9 months. Sensitivity decreased by 9.6% from 92.9 to 83.3% when only 1 V was used for evaluation (p < 0.001). The lower limit of the 90% confidence interval around the difference in sensitivity between 1 V and 2 V readings was - 15% and lies below the predefined non-inferiority margin of - 10%. Hence, non-inferiority of 1 V to 2 V reading cannot be concluded. AUC for 1 V was significantly lower, 0.861 versus 0.899 for 2 V (p = 0.0174).
Conclusion:
Non-inferiority of 1 V evaluations as an alternative reading strategy to standard 2 V evaluations could not be concluded. 1 V evaluations had lower diagnostic performance compared with 2 V evaluations.
Key Points:
• To lower radiation exposure used in contrast-enhanced mammography, we studied a hypothetical alternative strategy: single-view readings (1 V) versus (standard) double-view readings (2 V). • Based on our predefined margin of - 10%, non-inferiority of 1 V could not be concluded. • 1 V evaluation is not recommended as an alternative reading strategy to lower CEM-related radiation exposure.
More Related Videos
08:22Combined Intravital Microscopy and Contrast-enhanced Ultrasonography of the Mouse Hindlimb to Study Insulin-induced Vasodilation and Muscle Perfusion
Published on: March 20, 2017
11:38In vivo Imaging of Optic Nerve Fiber Integrity by Contrast-Enhanced MRI in Mice
Published on: July 22, 2014
Related Concept Videos
Self-Evaluation: Self-Enhancement and Self-Verification
Uncertainty in Measurement: Reading Instruments
Econometric Views (EViews)
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Cranial Bones: Lateral View
The temporal bone forms the lower lateral side of the skull. The temporal bone is subdivided into several regions. The flattened upper portion is the squamous portion of the temporal bone. Below this area and projecting anteriorly is the zygomatic process of the temporal bone, which forms the posterior portion of the zygomatic arch. Posteriorly is the mastoid portion of the temporal bone. Projecting...
Revisionist Views of Adolescent and Adult Cognition