Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Diffusion01:12

Diffusion

217.1K
Diffusion is the passive movement of substances down their concentration gradients—requiring no expenditure of cellular energy. Substances, such as molecules or ions, diffuse from an area of high concentration to an area of low concentration in the cytosol or across membranes. Eventually, the concentration will even out, with the substance moving randomly but causing no net change in concentration. Such a state is called dynamic equilibrium, which is essential for maintaining overall...
217.1K
Diffusion01:21

Diffusion

6.3K
Diffusion is a type of passive transport. In passive transport, a substance tends to move from an area of high concentration to an area of low concentration until the concentration is equal across the space. For example, take the diffusion of substances through the air. When someone opens a perfume bottle in a room filled with people, the perfume is at its highest concentration in the bottle and is at its lowest at the edges of the room. The perfume vapor will diffuse, or spread away, from the...
6.3K
Distance Corrections01:15

Distance Corrections

285
To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
285
Power Factor Correction01:20

Power Factor Correction

510
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
510
¹H NMR: Interpreting Distorted and Overlapping Signals01:02

¹H NMR: Interpreting Distorted and Overlapping Signals

1.5K
Spin systems where the difference in chemical shifts of the coupled nuclei is greater than ten times J are called first-order spin systems. These nuclei are weakly coupled, and their chemical shifts and coupling constant can generally be estimated from the well-separated signals in the spectrum.
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
1.5K
Facilitated Diffusion01:16

Facilitated Diffusion

1.2K
The plasma membrane, a critical structure in cellular biology, houses an array of transporters, or carrier proteins, interspersed within its lipid bilayer. These proteins play a crucial role in solute transport through facilitated diffusion, a form of passive diffusion that uses transporters to move the molecules across the membrane.
In this process, substrates such as organic compounds and ions interact with a transporter on one side, triggering conformational changes in proteins that enable...
1.2K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

<i>Erratum</i> to: "Isatuximab plus bortezomib, lenalidomide, and dexamethasone for transplant-ineligible newly diagnosed multiple myeloma patients: a frailty subgroup analysis of the IMROZ trial".

Haematologica·2026
Same author

DeepFixel: Crossing white matter fiber identification through spherical convolutional neural networks.

Proceedings of SPIE--the International Society for Optical Engineering·2026
Same author

HARMONIZATION MITIGATES DIFFUSION MRI SCANNER EFFECTS IN INFANCY: INSIGHTS FROM THE HEALTHY BRAIN AND CHILD DEVELOPMENT (HBCD) STUDY.

Proceedings. IEEE International Symposium on Biomedical Imaging·2026
Same author

HARMONIZATION MITIGATES DIFFUSION MRI SCANNER EFFECTS IN INFANCY: INSIGHTS FROM THE HEALTHY BRAIN AND CHILD DEVELOPMENT (HBCD) STUDY.

ArXiv·2026
Same author

Isatuximab, bortezomib, lenalidomide, and dexamethasone for multiple myeloma: dynamics of MRD negativity in the IMROZ study.

Blood·2026
Same author

Low-Cost and Detunable Wireless Resonator Glasses for Enhanced Eye MRI With Concurrent High-Quality Whole-Brain MRI.

Magnetic resonance in medicine·2026
Same journal

Repeatability of an MRI protocol for generating habitats based on cellularity, perfusion, and hypoxia in a murine model of glioma.

Magnetic resonance imaging·2026
Same journal

Association between CMR-derived pulmonary artery pulse wave velocity and pulmonary risk factors: the multi-ethnic study of atherosclerosis COPD study.

Magnetic resonance imaging·2026
Same journal

Systematic comparison of MPRAGE and BRAVO T1-weighted MRI pulse sequences and brain morphometry in high-risk young adults.

Magnetic resonance imaging·2026
Same journal

Foot dynamic contrast-enhanced MRI for assessing microcirculatory changes after endovascular therapy in peripheral artery disease: A prospective pilot study.

Magnetic resonance imaging·2026
Same journal

Reconstruction of MRI from undersampled k-spaces of double-contrast volume acquisitions using deep neural networks.

Magnetic resonance imaging·2026
Same journal

Radiofrequency-induced heating safety of brain MRI scans at 7 T in the presence of a shoulder implant.

Magnetic resonance imaging·2026
See all related articles

Related Experiment Video

Updated: Jan 25, 2026

Advanced Diffusion Imaging in The Hippocampus of Rats with Mild Traumatic Brain Injury
10:33

Advanced Diffusion Imaging in The Hippocampus of Rats with Mild Traumatic Brain Injury

Published on: August 14, 2019

9.0K

Synthesized b0 for diffusion distortion correction (Synb0-DisCo).

Kurt G Schilling1, Justin Blaber2, Yuankai Huo3

  • 1Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, TN, United States of America.

Magnetic Resonance Imaging
|May 11, 2019
PubMed
Summary
This summary is machine-generated.

This article introduces a deep learning method called Synb0-DisCo that corrects spatial distortions in brain scans. Standard correction techniques require extra, specialized imaging data that are often missing from historical or limited datasets. By using structural brain images to create a synthetic target, this approach allows researchers to fix distortions in older data without needing the additional scans. This improves the accuracy of brain mapping and ensures that diffusion images align correctly with anatomical structures.

Keywords:
Conditional generative networkDiffusion MRIDistortion correctionEcho planar imagingImage synthesisdiffusion imagingsusceptibility artifactsdeep learningbrain mappingimage processing

Frequently Asked Questions

More Related Videos

Measuring the Complete-arch Distortion of an Optical Dental Impression
06:51

Measuring the Complete-arch Distortion of an Optical Dental Impression

Published on: May 30, 2019

8.0K
Diffusion Imaging in the Rat Cervical Spinal Cord
10:46

Diffusion Imaging in the Rat Cervical Spinal Cord

Published on: April 7, 2015

12.2K

Related Experiment Videos

Last Updated: Jan 25, 2026

Advanced Diffusion Imaging in The Hippocampus of Rats with Mild Traumatic Brain Injury
10:33

Advanced Diffusion Imaging in The Hippocampus of Rats with Mild Traumatic Brain Injury

Published on: August 14, 2019

9.0K
Measuring the Complete-arch Distortion of an Optical Dental Impression
06:51

Measuring the Complete-arch Distortion of an Optical Dental Impression

Published on: May 30, 2019

8.0K
Diffusion Imaging in the Rat Cervical Spinal Cord
10:46

Diffusion Imaging in the Rat Cervical Spinal Cord

Published on: April 7, 2015

12.2K

Area of Science:

  • Neuroimaging methodology within Synb0-DisCo research
  • Computational neuroscience and diagnostic medical imaging

Background:

Diffusion magnetic resonance imaging often exhibits spatial warping caused by magnetic field inhomogeneities. These artifacts compromise the spatial precision of reconstructed brain volumes. Such errors frequently lead to misalignments between functional data and high-resolution anatomical scans. Current gold-standard correction techniques rely on acquiring paired images with opposing phase-encoding polarities. Many existing clinical protocols fail to collect these specific dual-polarity datasets. This limitation prevents the application of robust motion and susceptibility mitigation strategies. No prior work had resolved the challenge of correcting single-direction acquisitions using only standard structural inputs. That uncertainty drove the development of a synthetic approach to bridge this diagnostic gap.

Purpose Of The Study:

The study aims to enable advanced susceptibility correction for diffusion imaging data that lack specialized acquisition sequences. Many historical datasets contain only single-direction diffusion scans and structural images, preventing the use of standard distortion correction algorithms. This gap motivated the development of a deep learning method to synthesize an undistorted reference volume. By creating a synthetic target from structural data, the researchers intend to provide a reliable anatomical guide for spatial alignment. The project seeks to demonstrate that this synthetic approach can match the performance of traditional dual-polarity techniques. The authors address the need for improved geometric fidelity in datasets with limited acquisition protocols. This work provides a solution for researchers attempting to integrate legacy scans into modern neuroimaging pipelines. The primary goal is to enhance the utility of existing clinical data through computational synthesis.

Main Methods:

The investigators designed a deep learning architecture to predict undistorted non-diffusion weighted volumes. This framework relies on structural inputs to generate a synthetic reference for spatial alignment. The team evaluated the pipeline by comparing corrected outputs against standard dual-polarity processing results. They utilized a large collection of brain scans to train the underlying neural network. The approach focuses on mapping warped single-direction data to a geometrically accurate anatomical space. Validation involved assessing the spatial overlap between corrected diffusion volumes and high-resolution structural templates. The study also quantified the impact of the correction on downstream diffusion modeling parameters. This review approach synthesizes performance metrics across multiple testing scenarios to confirm reliability.

Main Results:

The synthetic correction process achieves geometric alignment nearly equivalent to traditional blip-up blip-down acquisition methods. The model successfully reduces spatial warping in single-direction diffusion scans using only structural inputs. Quantitative assessments show that the synthetic target improves the matching of diffusion volumes to anatomical references. The researchers observed a significant reduction in variability within diffusion modeling outputs after applying this correction. The deep learning framework effectively synthesizes an undistorted non-diffusion weighted image from structural data. This approach enables robust susceptibility correction for datasets that previously lacked the necessary acquisition parameters. The results demonstrate that the synthetic method maintains high fidelity across diverse brain imaging samples. These findings confirm that the pipeline is a practical solution for processing limited or historical neuroimaging archives.

Conclusions:

The authors propose that their synthetic framework effectively mitigates susceptibility-induced spatial warping in diffusion datasets. This approach facilitates the processing of historical scans lacking specialized dual-polarity acquisition sequences. The researchers demonstrate that their method achieves geometric alignment comparable to traditional, data-intensive correction pipelines. By leveraging structural information, the model provides a viable alternative for improving image fidelity. The findings suggest that synthetic targets reduce variability in subsequent diffusion modeling tasks. This technique expands the utility of limited datasets in large-scale neuroimaging studies. The synthesis process maintains high fidelity relative to established, acquisition-heavy standards. Future applications may benefit from applying this pipeline to diverse clinical cohorts with constrained imaging protocols.

The researchers propose using deep learning to generate a synthetic, undistorted non-diffusion weighted image from structural scans. This synthetic target serves as a reference to correct spatial warping in single-direction diffusion data, effectively mimicking the performance of traditional dual-polarity acquisition methods.

The method utilizes T1-weighted structural images as the primary input. These anatomical scans provide the necessary spatial information to synthesize an undistorted reference volume, which is then used to guide the correction of diffusion-weighted images that lack reverse phase-encoding pairs.

A structural image is necessary because it provides a geometrically accurate anatomical template. Without this reference, the deep learning model cannot synthesize the undistorted non-diffusion weighted volume required to align the warped diffusion data with the patient's actual anatomy.

The synthetic non-diffusion weighted image acts as a target for the distortion correction algorithm. By providing this undistorted reference, the model allows the pipeline to estimate and remove susceptibility-induced artifacts from single-direction diffusion scans, achieving results similar to those obtained with blip-up blip-down data.

The authors measured the efficacy of their approach by comparing the geometric alignment of corrected images against anatomical references. They also assessed the reduction in variability during diffusion modeling, confirming that the synthetic method performs nearly identically to standard dual-polarity acquisition protocols.

The researchers claim that this framework enables the inclusion of historical or limited datasets in advanced neuroimaging analyses. By removing the requirement for specialized acquisition sequences, the method allows for more comprehensive use of existing clinical archives in brain research.