Related Experiment Video
Updated: Jan 25, 2026

Test Samples for Optimizing STORM Super-Resolution Microscopy
Published on: September 6, 2013
Electrical storm is associated with impaired prognosis compared to ventricular tachyarrhythmias
Michael Behnes1, Julian Müller1, Dominik Ellguth1
1First Department of Medicine, University Medical Centre Mannheim (UMM), Faculty of Medicine Mannheim, University of Heidelberg, European Center for AngioScience (ECAS), and DZHK (German Center for Cardiovascular Research) partner site Heidelberg/Mannheim, Mannheim, Germany.
Background:
Because data on electrical storm (ES) is limited, this study sought to compare the prognosis of patients with ES to those with ventricular tachyarrhythmias on mortality, rehospitalization and major adverse cardiac events (MACE).
Methods:
In this retrospective study consecutive implantable cardioverter defibrillator (ICD) recipients presenting with ES were compared to patients surviving ventricular tachyarrhythmias (ventricular tachycardia (VT) or fibrillation (VF); non-ES) on admission from 2002 to 2016. The primary endpoint was all-cause mortality, secondary endpoints were rehospitalization and MACE at 2.5 years of follow-up.
Results:
764 consecutive patients with an ICD were included (11% with ES, 89% with VTA). ES was associated with higher rates of all-cause mortality (37% vs. 20%, log-rank p = 0.001; HR 2.084; 95% CI 1.416-3.065, p = 0.001). However, only in secondary preventive ICD recipients, ES remained significantly associated with mortality (39% vs. 20%; log rank p = 0.001; HR 2.235, 95% CI 1.378-3.625, p = 0.001). Furthermore, ES was associated with higher rates of rehospitalization (44% vs. 12%, log-rank p = 0.001; HR 4.763, 95% CI 3.237-7.009, p = 0.001), mainly due to VT (22% vs. 4%, p = 0.001) and acute heart failure (AHF) (17% vs. 4%, p = 0.001) and higher rates of MACE (40% vs. 23%; log rank p = 0.001; HR 1.838; 95% CI 1.273-2.654, p = 0.002). Increasing risks of death and rehospitalization were still observed even after multivariable adjustment.
Conclusion:
ES was associated with increased rates of all-cause mortality, rehospitalization, respectively due to VT and AHF, as well as MACE at 2.5 years compared to patients with ventricular tachyarrhythmias apart from ES.
Related Concept Videos
Dysrhythmias II: Classification of Tachyarrhythmias
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...
Determining Electric Field From Electric Potential
In general, regardless of whether the electric field is uniform, it points in the direction of decreasing potential because the force on a positive...
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Finding Electric Potential From Electric Field
Comparing the Survival Analysis of Two or More Groups