Related Experiment Video
Updated: Jan 25, 2026

Mouse Model of Pressure Ulcers After Spinal Cord Injury
Published on: March 9, 2019
Bioengineering considerations in the prevention of medical device-related pressure ulcers
D L Bader1, P R Worsley1, A Gefen2
1School of Health Sciences, University of Southampton, Southampton, UK.
Background:
In recent years, it has become increasingly apparent that medical device-related pressure ulcers represent a significant burden to both patients and healthcare providers. Medical devices can cause damage in a variety of patients from neonates to community based adults. To date, devices have typically incorporated generic designs with stiff polymer materials, which impinge on vulnerable soft tissues. As a result, medical devices that interact with the skin and underlying soft tissues can cause significant deformations due to high interface pressures caused by strapping or body weight.
Methods:
This review provides a detailed analysis of the latest bioengineering tools to assess device related skin and soft tissue damage and future perspectives on the prevention of these chronic wounds. This includes measurement at the device-skin interface, imaging deformed tissues, and the early detection of damage through biochemical and biophysical marker detection. In addition, we assess the potential of computational modelling to provide a means for device design optimisation and material selection.
Interpretation:
Future collaboration between academics, industrialists and clinicians should provide the basis to improve medical device design and prevent the formation of these potentially life altering wounds. Ensuring clinicians report devices that cause pressure ulcers to regulatory agencies will provide the opportunity to identify and improve devices, which are not fit for purpose.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Design Consideration
The factor of safety is another key...
Peptic Ulcer Disease II: Pathophysiology
Damaging agents such as Helicobacter pylori, gastric acid, pepsin, and nonsteroidal anti-inflammatory drugs (NSAIDs) can weaken the mucosal defense, allowing hydrogen ions to infiltrate back and harm epithelial cells.
Cancer Prevention
Some...
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...
Transmission Line Design Considerations

