Coronary plaque composition assessed by cardiac computed tomography using adaptive Hounsfield unit thresholds
Related Experiment Video
Updated: Jan 25, 2026

Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
Martina Chantal de Knegt1, Morten Haugen1, Andreas Kryger Jensen2
1Department of Cardiology, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark.
Purpose:
Quantitative computed tomography (QCT) may be useful in detecting high-risk patients with coronary atherosclerosis. Assessment of plaque composition using fixed Hounsfield unit (HU) thresholds is influenced by luminal contrast density. A method using adaptive HU thresholds has therefore been developed. This study investigates agreement between plaque volumes derived using fixed and adaptive HU thresholds and the influence of luminal contrast density on the determination of plaque composition.
Methods:
We performed QCT in 260 patients with recent acute-onset chest pain without acute coronary syndrome. Plaque volumes of necrotic core (NC), fibrous fatty (FF), fibrous (FI) and dense calcium (DC) tissue were measured in 1161 coronary segments. Agreement between plaque volumes using fixed and adaptive HU thresholds was tested using the Bland-Altman method. Additionally, patients were stratified into tertiles of ascending aortic luminal contrast density and plaque volumes were compared.
Results:
Bland-Altman plots revealed that fixed HU thresholds underestimated FI and FF plaque volumes and overestimated NC and DC plaque volumes compared to adaptive HU thresholds. Volumes of dense calcium plaque differed with increasing tertiles of luminal contrast density when using fixed HU thresholds but not when using adaptive HU thresholds: DC for fixed HU thresholds (mm3, median (95%CI)): 7.73 (5.17;12.31), 9.83 (6.55;13.57), 12.02 (8.26;16.24); DC for adaptive HU thresholds (mm3, median (95%CI)): 7.34 (5.12;12.03), 7.78 (5.40;12.61), 8.56 (5.22;12.69).
Conclusions:
Plaque volumes by fixed and adaptive HU thresholds differed. Plaque volumes by adaptive HU thresholds were more independent of luminal contrast density for higher attenuation tissues compared to fixed HU thresholds.
More Related Videos
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Classifying Matter by Composition
According to its composition, the matter can be classified into two broad categories — pure substances and mixtures.
A pure substance is a form of matter that has a constant composition throughout with uniform properties. For example, any sample of sucrose has the same composition and same physical properties, such as melting point, color, and sweetness, regardless of the source from which it is isolated.
A mixture is composed of two or...