Related Experiment Video
Updated: Jan 25, 2026

Evaluating Flight Performance and Eye Movement Patterns Using Virtual Reality Flight Simulator
Published on: May 19, 2023
Three days of training with a low-fidelity arthroscopy triangulation simulator box improves task performance in a
Samy Bouaicha1, Susanne Epprecht2, Thorsten Jentzsch2
1Department of Orthopedics, Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008, Zurich, Switzerland. samy.bouaicha@balgrist.ch.
Purpose:
The aim of this work is to evaluate the effectiveness of training with the low-fidelity ArthroBox® regarding performance of different basic arthroscopy tasks using a validated high-fidelity virtual reality simulator of the knee.
Methods:
Nineteen volunteers (14 females and 5 males) without any previous experience in arthroscopy were randomly assigned either to the ArthroBox® training group (n =10) or the non-training group (n =9). The training group underwent a supervised ArthroBox ® training consisting of a daily 60-min session for three consecutive days. Both groups completed the basic and the final assessment using a validated virtual reality-based passive haptic knee arthroscopy simulator (ArthroS, VirtaMed™). The following three factors were measured in different exercises (explained in "Materials and methods"): amount of time to finish the task, length of camera and scope path within the joint. Furthermore, the volunteers' demographics (age, sex, dexterity, video game experience, sport activities and profession) was assessed but showed no differences between the groups.
Results:
There were no significant differences between the training and non-training group regarding the above-mentioned demographic factors. However, the training group showed significant improvement from baseline to follow-up in most activities (e.g. task performance time in seconds, intra-articular camera and grasp distance in centimetres; see Table 1) in comparison to the non-training group.
Conclusions:
The results from this study demonstrate that training for three consecutive days using a portable and versatile low-fidelity simulator significantly improves arthroscopy performance when using a validated high-fidelity virtual knee simulator. Arthroscopic triangulation training outside the operating theatre with a portable, low-cost simulator has proven to be a valuable educational tool to improve the arthroscopic skills of trainee surgeons.
Level Of Evidence:
Diagnostic study, Level II.
Related Concept Videos
Virtual Work
In static equilibrium, a body can experience an imaginary or virtual movement, such as displacement or rotation. The virtual work done by a force is equal to the dot product of force and virtual displacement in the direction of the force. When it comes to virtually rotating a...
Principle of Virtual Work: Problem Solving
To apply the principle of virtual work,...
Virtual Work for a System of Connected Rigid Bodies
Next,...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...
Microsoft Excel: Median, Quartile range, and Box Plots
Median and Quartile Range: The median is calculated using the formula `=MEDIAN(range)', which provides the middle value of your data set. Quartiles divide your data into four equal parts. To find the first and third quartiles, use ‘=QUARTILE(range, 1)' and ‘=QUARTILE(range, 3)', respectively. The interquartile range (IQR), which...

