Background And Aims:
Acute upper GI bleeding is common and requires investigation with EGD, but endotherapy is not always necessary. Magnetically assisted capsule endoscopy (MACE) uses a capsule steerable by an external magnet and allows examination of the upper GI tract and small bowel, but its role in acute upper GI bleeding has not been assessed.
Methods:
We conducted a prospective cohort study comparing the diagnostic yield of MACE and EGD in patients with suspected acute upper GI bleeding. Patient tolerance, mucosal visibility by MACE, and frequency of small-bowel bleeding were assessed. Whether or not MACE could safely predict discharge of patients was also determined.
Results:
Thirty-three patients were included for analysis (median age, 60 years; 75.8% male). MACE detected more focal lesions (peptic, vascular, and fresh/altered blood without a clear source) than EGD (40 versus 25, respectively, P = .02) but statistical significance was not reached for significant lesions (considered to be the bleeding source; 14 vs 13, respectively, P = 1). Capsule endoscopy identified an additional cause for bleeding in the small bowel in 18%. Visualization by MACE was excellent in most areas; views of the esophagus, gastroesophageal junction, fundus, and duodenal bulb were suboptimal. MACE was better tolerated than unsedated EGD and correctly identified patients who were safe for discharge.
Conclusions:
MACE had higher diagnostic yield for focal lesions and was better tolerated than EGD. It also correctly predicted safe discharge for patients with acute upper GI bleeding. (Clinical trials registration number: NCT02690376.).
Related Concept Videos
Endoscopic Procedures III: Video Capsule Endoscopy
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Bleeding in Fresh Concrete
Bleeding can cause several issues in the concrete structure. Sometimes, the rising water gets trapped beneath large aggregate...
Arteries of the Upper Limbs
Veins of Upper Limbs
The deep venous system is primarily composed of the ulnar and radial veins. The ulnar vein, which drains the fingers through the superficial palmar venous arches, and the radial vein, which serves the palms via the deep palmar...
Intracellular Signaling Affects Focal Adhesions
Some...