Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Standard Electrode Potentials03:02

Standard Electrode Potentials

50.0K
On comparing the reactivity of silver and lead, it is observed that the two ionic species, Ag+ (aq) and Pb2+ (aq), show a difference in their redox reactivity towards copper: the silver ion undergoes spontaneous reduction, while the lead ion does not. This relative redox activity can be easily quantified in electrochemical cells by a property called cell potential. This property is commonly known as cell voltage in electrochemistry, and it is a measure of the energy which accompanies the charge...
50.0K
What are Estimates?01:06

What are Estimates?

8.2K
It isn't easy to measure a parameter such as the mean height or the mean weight of a population. So, we draw samples from the population and calculate the mean height or mean weight of the individuals in the sample. This sample data acts as a representative measure of the population parameter. These sample statistics are known as estimates. 
The estimate for the mean of a sample is denoted by ͞x, whereas the mean of the population is designated as μ. Further, parameters such...
8.2K
Dry Friction01:30

Dry Friction

945
Dry friction occurs between two solid surfaces in contact as they attempt to move relative to one another. In daily life, dry friction is encountered in various forms, such as when walking on the ground, sliding an object across a table, or rubbing hands together. Despite its ubiquity, the underlying mechanisms behind dry friction are not readily visible.
To illustrate this concept, imagine a wooden crate resting on a rough, non-uniform horizontal surface. When an external force is applied to...
945
Drying Shrinkage01:21

Drying Shrinkage

365
When hardened concrete is exposed to air with a relative humidity of less than 100 percent, it begins to lose the free water within its capillaries. As this water evaporates, the water initially adsorbed onto the calcium silicate hydrates migrates towards these now empty spaces and eventually evaporates as well. Over time, as more water leaves, the volume of the concrete decreases, a phenomenon known as drying shrinkage.
A portion of this drying shrinkage can be reversed; if the concrete is...
365
Estimation of k and VD of Aminoglycosides01:20

Estimation of k and VD of Aminoglycosides

220
Aminoglycosides are a class of antibiotics used to treat various bacterial infections. Clinicians must determine the elimination rate constant (k) and volume of distribution (VD) to optimize therapeutic efficacy and minimize toxicity. The k value represents the rate at which the drug is removed from the body, and the VD reflects the degree to which the drug distributes into body tissues. Accurately estimating these parameters allows healthcare professionals to tailor drug dosing to individual...
220
Electrodes: Overview01:17

Electrodes: Overview

2.6K
 Electrochemical measurements are conducted in an electrochemical cell composed of various components that control and measure the current and potential. One fundamental component is electrodes, conductive materials that enable electron transfer reactions at their surfaces.
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
2.6K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

GoP-Based Quality Enhancement on Video Compression.

IEEE transactions on image processing : a publication of the IEEE Signal Processing Society·2026
Same author

Development of an osteo-angiogenic scaffold derived from decellularization of spheroid-embedded 3D constructs for vascularized bone regeneration.

Materials horizons·2026
Same author

Mapping Physical Fitness Assessments in Interventional Research Among Breast Cancer Survivors: A Scoping Review.

Cancers·2026
Same author

Designing an mHealth App for Defecatory Function Rehabilitation of Post-Surgical Colorectal Cancer Survivors.

Journal of healthcare informatics research·2026
Same author

Deep Learning-based Volition Detection and Action Potential Extraction for Fully Automated Diagnosis of Neuromuscular Disease Using Needle Electromyography Signals.

IEEE transactions on computational biology and bioinformatics·2026
Same author

Effect of early exercise on functional recovery and surgical outcomes after post-mastectomy breast reconstruction: study protocol for a randomized clinical trial.

BMC cancer·2026

Related Experiment Video

Updated: Jan 25, 2026

A Community-based Stress Management Program: Using Wearable Devices to Assess Whole Body Physiological Responses in Non-laboratory Settings
10:45

A Community-based Stress Management Program: Using Wearable Devices to Assess Whole Body Physiological Responses in Non-laboratory Settings

Published on: January 22, 2018

8.1K

Dry Electrode-Based Body Fat Estimation System with Anthropometric Data for Use in a Wearable Device.

Seung-Chul Shin1, Jinkyu Lee2, Soyeon Choe3

  • 1The Department of Electrical and Electronic Engineering, Yonsei University, Shinchon-dong, Seodaemun-gu, Seoul 03722, Korea. sc1225.shin@yonsei.ac.kr.

Sensors (Basel, Switzerland)
|May 15, 2019
PubMed
Summary

A new wearable device offers a faster and more accurate way to measure body fat percentage (PBF) using bioelectrical impedance analysis (BIA). This innovative method simplifies measurements, improving accuracy and reducing time compared to traditional BIA devices.

Keywords:
bioelectrical impedance analysisdeep learningpercent body fatsettling value estimationupper-body measurement

More Related Videos

Conformable Wearable Electrodes: From Fabrication to Electrophysiological Assessment
10:03

Conformable Wearable Electrodes: From Fabrication to Electrophysiological Assessment

Published on: July 22, 2022

5.0K
Evaluation of Commercial-Off-The-Shelf Wrist Wearables to Estimate Stress on Students
12:51

Evaluation of Commercial-Off-The-Shelf Wrist Wearables to Estimate Stress on Students

Published on: June 16, 2018

7.9K

Related Experiment Videos

Last Updated: Jan 25, 2026

A Community-based Stress Management Program: Using Wearable Devices to Assess Whole Body Physiological Responses in Non-laboratory Settings
10:45

A Community-based Stress Management Program: Using Wearable Devices to Assess Whole Body Physiological Responses in Non-laboratory Settings

Published on: January 22, 2018

8.1K
Conformable Wearable Electrodes: From Fabrication to Electrophysiological Assessment
10:03

Conformable Wearable Electrodes: From Fabrication to Electrophysiological Assessment

Published on: July 22, 2022

5.0K
Evaluation of Commercial-Off-The-Shelf Wrist Wearables to Estimate Stress on Students
12:51

Evaluation of Commercial-Off-The-Shelf Wrist Wearables to Estimate Stress on Students

Published on: June 16, 2018

7.9K

Area of Science:

  • Biomedical Engineering
  • Wearable Technology
  • Body Composition Analysis

Background:

  • Bioelectrical impedance analysis (BIA) is a common method for estimating percent body fat (PBF).
  • Traditional BIA methods often require multiple electrodes and lengthy measurement times.
  • Existing wearable devices face challenges with accuracy and measurement consistency due to parasitic resistance and posture variations.

Purpose of the Study:

  • To develop a faster, more accurate wearable device for PBF prediction using BIA.
  • To utilize upper-body impedance to predict whole-body impedance, simplifying the measurement process.
  • To minimize measurement variations through a novel sensing system and reduce measurement time.

Main Methods:

  • A small, dry electrode-based wearable device was designed, focusing on wrist and index finger contact.
  • A parameter calibration network was employed to reduce measurement time to five seconds.
  • A deep neural network algorithm integrated upper-body impedance with lower-body anthropometric data for PBF prediction.

Main Results:

  • The proposed system demonstrated improved performance compared to two commercial BIA systems.
  • A significant improvement in the correlation coefficient (r²) of approximately 9% was observed.
  • The standard error of estimate (SEE) was reduced by 28%, indicating enhanced prediction accuracy.

Conclusions:

  • The novel wearable BIA device offers a more efficient and accurate method for PBF assessment.
  • The deep neural network approach effectively predicts PBF using limited impedance data and auxiliary features.
  • This technology has the potential to enhance personal health monitoring and athletic performance tracking.