Proposal for a chemically consistent way to annotate ions arising from the analysis of reference compounds under ESI

Annelaure Damont1, Marie-Françoise Olivier1, Anna Warnet1

  • 1Service de Pharmacologie et Immuno-Analyse (SPI), Laboratoire d'Etude du Métabolisme des Médicaments, CEA, INRA, Université Paris Saclay, MetaboHUB, F-91191, Gif-sur-Yvette, France.

Related Concept Videos

Formula Mass and Mole Concepts of Compounds02:56

Formula Mass and Mole Concepts of Compounds

Formula Mass of Covalent Compounds
80.8K
Coordination Compounds and Nomenclature02:54

Coordination Compounds and Nomenclature

In most main group element compounds, the valence electrons of the isolated atoms combine to form chemical bonds that satisfy the octet rule. For instance, the four valence electrons of carbon overlap with electrons from four hydrogen atoms to form CH4. The one valence electron leaves sodium and adds to the seven valence electrons of chlorine to form the ionic formula unit NaCl (Figure 1a). Transition metals do not normally bond in this fashion. They primarily form coordinate covalent bonds, a...
26.4K
Electrospray Ionization (ESI) Mass Spectrometry01:12

Electrospray Ionization (ESI) Mass Spectrometry

Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
2.2K
Lewis Structures of Molecular Compounds and Polyatomic Ions02:54

Lewis Structures of Molecular Compounds and Polyatomic Ions

To draw Lewis structures for complicated molecules and molecular ions, it is helpful to follow a step-by-step procedure as outlined:
44.9K
Chemical Shift: Internal References and Solvent Effects01:17

Chemical Shift: Internal References and Solvent Effects

In an NMR sample, precise measurement of the absolute absorption frequencies of nuclei is difficult. A standard internal reference compound is added, and the frequency difference between the reference signal and sample signals is measured.
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
1.3K
Ions, Molecules, and Compounds01:23

Ions, Molecules, and Compounds

Ions - When an atom participates in a chemical reaction that results in the donation or acceptance of one or more electrons, the atom becomes positively or negatively charged. This frequently happens for most atoms to have a full valence shell. This can happen either by gaining electrons to fill a shell that is more than half-full or by giving away electrons to empty a shell that is less than half-full, thereby leaving the next smaller electron shell as the new, full valence shell. An atom with...
12.7K