GC-ICP-MS/MS Instrumental Setup for Total and Speciation Sulfur Analysis in Gasolines using Generic Standards
Laura Freije-Carrelo1, Javier García-Bellido1, Francisco Calderón-Celis1
1Department of Physical and Analytical Chemistry , University of Oviedo , Julián Clavería 8 , 33006 Oviedo , Spain.
Abstract:
Quantitative characterization of sulfur-containing petroleum derivatives is mainly limited by the large number of potential targets present and the matrix effects suffered due to the high-carbon-containing matrices. Herein we describe the instrumental modifications required in a commercial GC-ICP-MS/MS instrument, and their corresponding optimization, for turning it into a compound-independent quantitative technique for both total and speciation sulfur analysis in gasolines. Additionally, carbon-derived matrix effects were made negligible for direct and fast total S analysis, making the use of relatively complex isotope-dilution strategies not necessary anymore. An absolute detection limit of 0.3 pg of S was achieved, which is, to the best of our knowledge, more than 1 order of magnitude below the ones reported for other sulfur GC selective detectors. The precision was below 3% RSD. Total analysis was performed by flow-injection analysis through a transfer line and external calibration, whereas speciation analysis was carried out by chromatographic separation and internal standardization. In both cases, simple generic standards were used, which enabled us to get rid of specific S-containing standards, which were sometimes not available or unstable. The proposed method was successfully applied to total and speciation sulfur analysis of a commercial gasoline sample and validated with a certified-reference-material (ERM-EF213) gasoline. The approach has proved to be simple, fast, robust, and convenient for implementation in routine laboratories, as demonstrated by the successive analyses of 50 gasoline samples in 3 h without any instrumental drift.
More Related Videos
04:48Setup of Capillary Electrophoresis-Inductively Coupled Plasma Mass Spectrometry CE-ICP-MS for Quantification of Iron Redox Species FeII, FeIII
Published on: May 4, 2020
06:00Biological Samples Preparation for Speciation at Cryogenic Temperature using High-Resolution X-Ray Absorption Spectroscopy
Published on: May 27, 2022
Related Concept Videos
Genetics of Speciation
Speciation Rates
The Sulfur Cycle
Sulfur Assimilation
Calculating Standard Free Energy Changes
Instrument Transformers