Related Experiment Video
Updated: Jan 25, 2026

Laser Microirradiation to Study In Vivo Cellular Responses to Simple and Complex DNA Damage
Published on: January 31, 2018
Will Stone Density Stop Being a Key Factor in Endourology? The Impact of Stone Density on Laser Time Using Lumenis
Matan Mekayten1, Amitay Lorber1, Ioannis Katafigiotis2
11 Urology Department, Hadassah Hebrew University Hospital, Jerusalem, Israel.
Abstract:
Ureteroscopy is the gold standard for most urinary tract calculi. Our institute recently incorporated a powerful 120 W holmium laser machine integrating innovative technology (Lumenis® MOSES PulseTM120H Holmium:YAG laser; Lumenis Ltd.). In this retrospective comparative study, we evaluated the influence of stone density on laser dusting time in a high-power 120 W laser machine vs a standard 20 W machine (Dornier Medilas® H20 Holmium:YAG laser; Dornier Ltd.) We conducted a retrospective review of medical records of patients who underwent ureteroscopy during the years 2013-2018 for a solitary stone. Stone and clinical characteristics, among other parameters, have been evaluated, including the total laser time until complete stone dusting. Among 631 eligible patients, 462 were treated with a 20 W standard laser and 169 patients with a p120w laser machine. Overall laser time was less than half with p120w laser vs d20w (195 seconds vs 397.14 seconds, p-value <0.001). Multivariate regression demonstrated 234.91 seconds shorter laser time with a p120w laser while controlling confounders such as stone volume, hydronephrosis, and location (p value <0.0001). This pattern was demonstrated in all stone densities. The association between laser dusting time per stone volume and stone density demonstrated relatively constant laser time when using p120w laser, even for hard stones. When the standard 20 W laser was used, laser time was longer in each stone density. Moreover, a stone density of 1164 HU and more demonstrated an upward shift of laser time to stone density curve in standard d20w laser group only. Time to complete stone dusting using p120w laser is extremely shorter, approximately half, comparing with the standard 20 W laser. This pattern is robust and even exponential when evaluating laser time per stone density, especially in hard stones. A new horizon of powerful innovative laser technology will enable to improve endourology practice and patients' care.
Related Concept Videos
Types of Building Stone
Igneous rocks are formed from the solidification of magma or lava. An example is granite, known for its durability and resistance to weathering, making it ideal for parts of...
Quarrying of Stone
One common method involves using a diamond belt saw to cut large blocks from the quarry face. These blocks can be about 50 feet long and 12 feet high. After the initial vertical cut, drilling is performed at the base of the...
Stone Masonry
Density
Current Density
Matrix-Assisted Laser Desorption Ionization (MALDI)

