Related Experiment Video
Updated: Aug 14, 2026

Diagnosis of Neoplasia in Barrett’s Esophagus using Vital-dye Enhanced Fluorescence Imaging
Published on: May 11, 2014
Endoscopists systematically undersample patients with long-segment Barrett's esophagus: an analysis of biopsy
Sachin Wani1, J Lucas Williams2, Srinadh Komanduri3
1Division of Gastroenterology and Hepatology, University of Colorado School of Medicine, Anschutz Medical Campus, Aurora, Colorado, USA.
Background And Aims:
Guidelines recommend systematic biopsy sampling in Barrett's esophagus (BE) to reduce sampling error. Adherence to this biopsy sampling protocol has been suggested as a quality indicator; however, estimates of adherence are not available. Using a national registry, we assessed adherence and identified predictors of adherence to biopsy sampling protocols.
Methods:
We analyzed data from the GI Quality Improvement Consortium Registry that included procedure indication, demographics, endoscopy, and pathology results. Patients with an indication of BE screening/surveillance or an endoscopic finding of BE were included. Adherence to the Seattle protocol was assessed by dividing BE length by number of pathology jars, with a ratio ≤2.0 with rounding down (lenient definition) or rounding up (stringent definition) for odd BE lengths considered adherent. Variables associated with adherence were assessed using generalized estimating equations to control for clustering within individual physicians.
Results:
Of 786,712 EGDs assessed, 58,709 (7.5%) EGDs in 53,541 patients met inclusion criteria (mean age, 61.3 years; 60.4% men; 90.2% white; mean BE length, 2.3 cm). When the lenient and stringent definitions for adherence were used, 87.8% and 82.7% of EGDs were adherent, respectively. Increasing BE length was the most significant predictor of nonadherence (odds ratio, .69; 95% confidence interval, .67-.71). Other predictors were increasing age, male gender, increasing American Society of Anesthesiologists class, and practice location. Performance of EGD by nongastroenterologist physicians was associated with nonadherence (odds ratio, .07; 95% confidence interval, .06-.10).
Conclusions:
Nearly 20% of endoscopies performed in BE patients were not adherent to the Seattle protocol. As BE length increases, endoscopists become less compliant with odds of nonadherence increasing by 31% with every 1-cm increase in length.
Related Concept Videos
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due to...
Barrett Esophagus-I: Introduction
This constant acid exposure transforms the esophagus's pink mucosal lining (stratified squamous epithelium) into a type of lining more similar...
Barrett Esophagus-II: Clinical Manifestations and Management
To diagnose Barrett's esophagus, healthcare providers often recommend an endoscopy for those showing symptoms of acid reflux. The procedure entails...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Endoscopic Procedures III: Video Capsule Endoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...