Permanent Percutaneous Carotid Artery Filter to Prevent Stroke in Atrial Fibrillation Patients: The CAPTURE Trial

Vivek Y Reddy1, Petr Neuzil2, Tom de Potter3

  • 1Department of Cardiology, Homolka Hospital, Prague, Czech Republic; Department of Cardiology, Icahn School of Medicine at Mount Sinai, New York, New York.

Insights

Permanent carotid filters offer a safe stroke prevention strategy for high-risk atrial fibrillation patients unsuitable for oral anticoagulants. The CAPTURE trial demonstrated technical feasibility and safety of bilateral filter placement.

Area of Science:

  • Cardiovascular Medicine
  • Medical Devices
  • Interventional Cardiology

Background:

  • Patients with atrial fibrillation and high stroke risk often cannot take oral anticoagulants (OACs).
  • Novel permanent coil filters are designed to capture emboli in the common carotid arteries (CCAs) to prevent stroke.
  • This technology targets embolic protection for patients ineligible for traditional OAC therapy.

Purpose of the Study:

  • To assess the feasibility and safety of bilateral common carotid artery (CCA) filter placement in patients with atrial fibrillation.
  • The CAPTURE trial evaluated a new embolic protection device for stroke prevention.
  • Determine the primary endpoints of procedural success and 30-day major adverse events.

Main Methods:

  • The multicenter, nonrandomized CAPTURE trial enrolled patients with atrial fibrillation and high stroke risk (CHA2DS2-VASc ≥2) unsuitable for OACs.
  • Bilateral CCA filter placement was performed under ultrasound guidance via transcutaneous carotid puncture.
  • Patients received dual antiplatelet therapy followed by aspirin, with follow-up including carotid ultrasounds.

Main Results:

  • Procedural success was achieved in 92% of 25 enrolled patients, with no device/procedure-related major adverse events.
  • Minor complications included puncture site hematomas/edema in 20% of patients.
  • Asymptomatic thrombi were detected in 4 patients post-procedure, all resolving with heparin therapy.

Conclusions:

  • Permanent carotid filter placement is a technically feasible and safe stroke prophylaxis method.
  • The CAPTURE trial supports the use of bilateral CCA filters for stroke prevention in specific patient populations.
  • This novel approach offers an alternative for patients with atrial fibrillation who cannot tolerate oral anticoagulants.
Abstract

Related Concept Videos

Amyloid Fibrils03:03

Amyloid Fibrils

Amyloid fibrils are aggregates of misfolded proteins.  Under most circumstances, misfolded proteins are either refolded by chaperone proteins or degraded by the proteasome. However, in the case of a mutation or a disease, these proteins can accumulate to form large clusters and often further assemble to form elongated fibers, called fibrils. 
Amyloid deposits were observed as early as 1639 in the liver and the spleen.   In 1854, Rudolph Virchow performed iodine staining,...
11.7K
Amyloid Fibrils03:03

Amyloid Fibrils

6.4K
Coronary Artery Disease IV: Preventive Measures01:26

Coronary Artery Disease IV: Preventive Measures

Effective preventive measures for coronary artery disease (CAD) focus on controlling modifiable risk factors, including cholesterol abnormalities and lifestyle changes.Cholesterol ManagementFirst, the Mediterranean diet and the American Heart Association advocate for maintaining low-density lipoprotein (LDL) cholesterol levels below 100 mg/dL, with a more stringent recommendation of below 70 mg/dL for individuals at high risk. LDL cholesterol, often termed "bad cholesterol," can lead to the...
615
Passive Filters01:27

Passive Filters

Passive filters are utilized to shape the frequency spectrum of signals across a diverse array of applications. These filters, using only passive elements like resistors (R), inductors (L), and capacitors (C), are capable of selectively allowing or blocking certain frequency ranges without the need for external power sources.
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
971
Active Filters01:25

Active Filters

Active filters are electronic circuits that use operational amplifiers (op-amps), resistors, and capacitors to filter out unwanted frequency components from a signal. A first-order low-pass active filter is designed to pass signals with a frequency lower than a certain cutoff frequency and attenuate frequencies higher than that cutoff frequency. The transfer function for a first-order low-pass active filter is:
1.3K
Fibril-associated Collagen01:11

Fibril-associated Collagen

Fibril-associated collagens are a type of collagens present in the extracellular matrix with interrupted triple helices or FACIT (Fibril-associated collagens interrupted triple-helices). FACIT help connect and attach the collagen fibrils with each other as well as with other proteins of the extracellular matrix.
For example, the type II collagen fibrils in cartilage have covalently bound type IX fibril-associated collagens at regular intervals. Other types of fibril-associated collagens are...
3.3K