Related Experiment Video
Updated: Jan 25, 2026

Observation and Analysis of Blinking Surface-enhanced Raman Scattering
Published on: January 11, 2018
Knee osteoarthritis grading by resonant Raman and surface-enhanced Raman scattering (SERS) analysis of synovial fluid
Corina D Bocsa1, Vlad Moisoiu2, Andrei Stefancu3
1Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania.
Abstract:
In this preliminary study on synovial fluid (SF), knee osteoarthritis (OA) grading of n = 23 patients was accomplished by combining two methods: resonant Raman spectroscopy, and surface-enhanced Raman scattering (SERS) of native proteins acquired with iodide-modified silver nanoparticles and a laser emitting at 633 nm. Based on principal component analysis-linear discriminant analysis (PCA-LDA), the SERS spectra of proteins enabled the classification of low-grade and high-grade OA groups with an accuracy of 91%. Resonant Raman spectra of SF, recorded with laser excitation at 532 nm, exhibited carotenoid-associated bands that were less intense in the case of high-grade knee OA patients. Based on the resonant Raman spectra, the grading of OA patients was accomplished with an accuracy of 74%. Concatenating SERS and Raman spectral information increased the classification accuracy between the two groups to 100%. These results demonstrate the potential of Raman and SERS as a point-of-care method for aiding OA grading.
More Related Videos
06:19Author Spotlight: Advancing SERS Technology: Au@Carbon Dot Nanoprobes for Label-Free Analysis and Imaging
Published on: June 9, 2023
10:59Author Spotlight: Tracking Electrochemistry on Single Nanoparticles with Surface-Enhanced Raman Scattering Spectroscopy and Microscopy
Published on: May 12, 2023
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Surface Tension of Fluid
Surface tension varies...
Sieve Analysis and Grading Curves
Resonance
Graded Potential
Graded potentials fall into two categories: depolarizing and hyperpolarizing. Depolarizing graded potentials typically occur when sodium (Na+) or...