Source contribution analysis of mercury deposition using an enhanced CALPUFF-Hg in the central Pearl River Delta,

Hui Xu1, Yun Zhu1, Long Wang1

  • 1Guangdong Provincial Key Laboratory of Atmospheric Environment and Pollution Control, College of Environment and Energy, South China University of Technology, Guangzhou Higher Education Mega Center, Guangzhou, 510006, China.

Related Concept Videos

The Delta-to-Delta Circuit01:17

The Delta-to-Delta Circuit

In a delta-delta configuration, the source and the load are connected in a delta manner, forming a closed loop that divides the network into three distinct phases. This configuration makes the phase voltages identical to line voltages. Assuming the sources are in positive sequence, the phase voltages can be expressed directly without having a neutral wire.
1.1K
Central Tendency: Analysis01:10

Central Tendency: Analysis

Measures of central tendency are tools used in biostatistics to identify the average or center of a dataset. They offer a single representative value for understanding and summarizing data distribution.
The mean is one such measure, calculated by totaling all values in a dataset and dividing by the number of values. For instance, the mean blood pressure reading (120, 130, 140, 150) would be 135. However, the mean can be affected by extreme values or outliers.
The median, another measure,...
488
The Y-to-Delta Circuit01:19

The Y-to-Delta Circuit

A balanced wye-to-delta circuit comprises balanced Y-connected voltage sources and delta-connected loads with no neutral line connection.
The initial step in analyzing a wye-to-delta circuit is to assume a positive phase sequence. These phase voltages are then utilized to calculate the line voltages that occur directly across the delta-connected load impedances. Van, Vbn, and Vcn are the phase voltages in wye, and Vab, Vbc, and Vca are the line voltages for a delta circuit. The relation between...
701
The Delta-to-Y Circuit01:16

The Delta-to-Y Circuit

In the delta-wye circuit, the source is delta-connected, while the load is in a wye configuration. This means that the phase voltage of the delta-connected source is equal to the line voltage of the wye-connected load. The connection between two-line currents originates from the delta-connected source. The phase difference in the balanced system allows for calculating one line current given the other, utilizing the positive sequence of phases. In the delta-wye system, the phase currents in the...
857
Mesh Analysis with Current Sources01:10

Mesh Analysis with Current Sources

Mesh analysis becomes simpler when analyzing circuits with current sources, whether independent or dependent. The presence of current sources reduces the number of equations required for analysis. Two cases illustrate this:
Current Source in One Mesh: The analysis process is straightforward when a current source is found in only one mesh within the circuit. Mesh currents are assigned as usual, with the mesh containing the current source excluded from the analysis. Kirchhoff's voltage law...
2.0K
Nodal Analysis with Voltage Sources01:11

Nodal Analysis with Voltage Sources

Nodal analysis is a remarkably effective method used in electrical engineering to simplify the analysis of complex circuits, including those with dependent or independent voltage sources. Its strength lies in its systematic approach to breaking down circuits into manageable components, making it easier for engineers to understand and solve.
Consider a circuit that contains four resistors and two voltage sources, as shown in Figure 1. One of these voltage sources is connected between a...
1.9K