Related Experiment Video
Updated: Jan 25, 2026

Supercritical Nitrogen Processing for the Purification of Reactive Porous Materials
Published on: May 15, 2015
Trueness assessment of HbA1c routine assays: are processed EQA materials up to the job?
Vincent Delatour1, Noémie Clouet-Foraison1,2, Stéphane Jaisson2
1Laboratoire National de Métrologie et d'Essais (LNE), Paris, France.
Abstract:
Background With the worldwide increase of diabetes mellitus prevalence, ensuring that HbA1c assays are accurate is essential. External quality assessment (EQA) programs enable laboratories to verify that analytical methods perform according to the manufacturers' specifications. However, assessing trueness requires commutable materials, a property that is rarely characterized for EQA materials. Methods The difference in bias approach was used to assess commutability of 26 processed quality control materials for 17 of the most frequently used HbA1c assays. Involved assays included immuno-assays, enzymatic assays, affinity, ion-exchange HPLC boronate affinity HPLC and capillary electrophoresis. The measurements were performed at manufacturers or expert laboratories. Assay trueness was additionally assessed against the IFCC reference measurement procedure using fresh clinical specimens that were distributed to 450 medical laboratories. Results Commutability of processed EQA materials was highly heterogeneous and globally insufficient to rigorously assess the trueness of HbA1c assays. Using fresh clinical specimens, mean bias was -0.13 mmol/mol for low HbA1c (34 mmol/mol), between +1.0 and +1.3 mmol/mol for intermediate HbA1c (49 and 58 mmol/mol) and +1.2 mmol/mol for elevated HbA1c (90 mmol/mol). Conclusions This study demonstrates that due to insufficient commutability, most processed EQA materials are unsuitable to assess trueness of HbA1c assays and agreement between the different assays. These materials can only provide information on comparability of individual laboratory results with its peers and on assay precision. Using fresh whole blood samples, this study additionally shows that most HbA1c assays are fairly accurate and meet the total allowable error quality target of 5 mmol/mol.
Related Concept Videos
Role of Communication in the Nursing Process I: Assessment and Diagnosis
The nursing process considers the patient's emotional and physical well-being. The process can be repeated or stopped at any point if judged essential. Assessment is the first step in the nursing...
Nursing Process for Patient and Caregiver Teaching I: Assessment and Diagnosis
It is critical to determine the patient's learning needs during the assessment. Determination of learning needs compounds data...
Members Made of Elastoplastic Material
As the bending moment...
Genetic Material
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...
Bending of Material: Problem Solving