Related Experiment Video
Updated: Jan 24, 2026

Measurement of the Hepatic Venous Pressure Gradient and Transjugular Liver Biopsy
Published on: June 18, 2020
Bedside hand vein inspection for noninvasive central venous pressure assessment
Franziska Vogel1, Daniel Staub1, Markus Aschwanden1
1Department of Angiology, University Hospital Basel, University of Basel, Basel, Switzerland.
Abstract:
Rapid estimates of the central venous pressure (CVP) can be helpful to administer early fluid therapy or to manage cardiac preload in intensive care units, operating rooms or emergency rooms in order to start and monitor an adequate medical therapy. Invasive CVP measurements have inherent and non-negligible complication rates as well as great expenditures. Several noninvasive methods of CVP measurements, like ultrasound-guided techniques, are available, but require trained skills and special equipment which might not be at hand in all situations. Our purpose was to evaluate the feasibility and accuracy of CVP estimates assessed upon the height of hand veins collapse (HVC) using invasively measured CVP as the gold standard. The HVC was determined by slowly lifting the patient's hand while watching the dorsal hand veins to collapse. The vertical distance from the dorsal hand to a transducer air zero port was noted and converted to mmHg. The observer was blinded to the simultaneously measured CVP values, which were categorized as low (<7 mmHg), normal (7-12 mmHg) and high (>12 mmHg). Measurements were performed in 82 patients who had a median [IQR] age of 67 [60;74]. Median CVP was 12 [8;15] mmHg and the median absolute difference between the measured HVC and CVP was 4 [2;7] mmHg. The Spearman correlation coefficient between CVP and HVC was 0.55, 95%-CI [0.35;0.69]. Overall CVP categorization was correct in 45% of the cases. HVC had a sensitivity of 92% for a low CVP with a negative predictive value of 98%. A high HVC had a sensitivity of 29% but a high specificity of 94% for a high CVP. The overall performance of observing the hand vein collapse to estimate CVP was only moderate in the intensive care setting. However, the median difference to the CVP was low and HVC identifies a low CVP with a high sensitivity and excellent negative predictive value.
More Related Videos
07:02A Rabbit Venous Interposition Model Mimicking Revascularization Surgery using Vein Grafts to Assess Intimal Hyperplasia under Arterial Blood Pressure
Published on: May 15, 2020
07:47The Supraclavicular Fossa Ultrasound View for Central Venous Catheter Placement and Catheter Change Over Guidewire
Published on: December 23, 2014
Related Concept Videos
Assessment of the Cardiovascular System II: Inspection
Head and Neck
Assessment of the Abdomen I: Inspection and Auscultation
The abdominal examination is a cornerstone of clinical medicine, serving as a critical tool in diagnosing various gastrointestinal (GI) diseases. It involves a systematic approach that includes inspection and auscultation, each with distinct yet complementary roles in assessing the abdomen. This article will delve into these two primary methods healthcare professionals use to examine the abdomen.
Inspection of the Abdomen
The first step in any abdominal examination is inspection....
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...
Nursing Assessment of the Genitourinary System II: Inspection and Palpation
Assessing Blood pressure in the Leg
Preparation:
Measures of Central Tendency