Related Experiment Video
Updated: Jan 24, 2026

Simultaneous Measurement of HDAC1 and HDAC6 Activity in HeLa Cells Using UHPLC-MS
Published on: August 10, 2017
[Simultaneous determination of 8 bioactive isoflavonoids in Astragali Radix by UHPLC equipped with core-shell column]
Dan Tang1, Dong-Min Cao1, Lan-Fang Tan1
1School of Traditional Chinese Medicine, Guangdong Pharmaceutical University Guangzhou 510006, China Key Laboratory of Digital Quality Evaluation of Chinese Materia Medica of SATCM Guangzhou 510006, China Engineering Technology Research Center for Chinese Materia Medica Quality of Guangdong Province Guangzhou 510006, China Engineering & Technology Research Center for Chinese Materia Medica Quality of the Universities of Guangdong Province Guangzhou 510006, China.
Abstract:
This research aims to develop an UHPLC method, based on core-shell column(i.e. superficially porous particles), for simultaneous determination of eight isoflavonoids including formononetin,(6αR,11αR)-3-hydroxy-9,10-dimethoxypterocarpan, calycosin-7-O-β-D-glucopyranoside,(3R)-7,2-dihydroxy-3,4-dimethoxyisoflavone, calycosin, ononin,(6αR,11αR)-9,10-dimethoxypterocarpan-3-O-β-D-glucopyranoside, and(3R)-7,2-dihydroxy-3,4-dimethoxyisoflavan-7-O-β-D-glucopyranoside in Astragali Radix. The analysis was performed on an Agilent Poroshell EC-C_(18 )column(2.1 mm×100 mm, 2.7 μm) with 0.2% formic acid solution(A)-acetonitrile(B) as mobile phase for gradient elution. The flow rate was 0.5 mL·min~(-1), with column temperature of 40 ℃ and the wavelengths were set at 260 and 280 nm. According to the results, all calibration curves showed good linearity(R~2>0.999 8) within the tested concentration ranges. Both the intra-and inter-day precisions for 8 isoflavonoids were less than 0.80%, with the mean recovery at the range of 94.71%-104.6%. Thus, the newly developed UHPLC method using core-shell column owned the advantages in terms of rapid analysis, low column pressure and less solvent consumption, thus enabling the usage of conventional HPLC systems. Meanwhile, quantitative evaluation was carried out for 22 batches of commercial Astragali Radix. It has been found that great variations occurred for the content of the individual isoflavonoids among different batches; in contrast, the total content of total 8 isoflavonoids(>0.1%) was stable in most samples, indicating that it was reasonable to involve all isoflavonoids as the chemical markers for the quality control of Astragali Radix.
More Related Videos
07:59Preparation of Nucleosome Core Particles Complexed with DNA Repair Factors for Cryo-Electron Microscopy Structural Determination
Published on: August 17, 2022
07:13Quantification of Violacein in Chromobacterium violaceum and Its Inhibition by Bioactive Compounds
Published on: August 8, 2025
Related Concept Videos
The Nucleosome Core Particle
The paradox
Nucleosomes, paradoxically, perform two opposite functions simultaneously. On the one hand, their main responsibility is to protect the delicate DNA strands from physical damage and help achieve a higher compaction ratio. While on the other hand, they must allow polymerase enzymes to access DNA...
The Nucleosome Core Particle
Nucleosomes, paradoxically, perform two opposite functions simultaneously. On the one hand, their primary aim is to protect the delicate DNA strands from physical damage and help achieve a higher compaction ratio. On the other hand, they must allow polymerase enzymes to access histone-bound DNA during...
Leveling Equipment
Personal Protective Equipment
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...