Related Experiment Video
Updated: Jan 24, 2026

High Resolution Phonon-assisted Quasi-resonance Fluorescence Spectroscopy
Published on: June 28, 2016
1.2 kW quasi-steady-state diamond Raman laser pumped by an M2 = 15 beam
Abstract:
An external cavity diamond Raman laser with 1.2 kW output power is demonstrated for durations 7 times longer than the thermal lens time constant. An 83% slope efficiency and a 53% optical-to-optical efficiency were obtained for conversion from a 1.06 μm pump to the 1.24 μm first Stokes. The pump had an M2 of 15, demonstrating that efficiency is maintained at the highest levels even when using exceptionally poor quality pumps. We show that a measured decrease in the output beam quality factor from M2=2.95 to M2=1.25 as power increased is evidence for thermal lens development in the diamond. The results foreshadow development of continuous-wave kilowatt-class lasers or amplifiers based on single diamond elements and pumped efficiently by lasers having poor spatial coherence such as line-narrowed diode laser arrays.
More Related Videos
09:06In vivo Imaging of Biological Tissues with Combined Two-Photon Fluorescence and Stimulated Raman Scattering Microscopy
Published on: December 20, 2021
10:59Label-Free Imaging of Lipid Storage Dynamics in Caenorhabditis elegans using Stimulated Raman Scattering Microscopy
Published on: May 28, 2021
Related Concept Videos
Steady State Concentration
Most drugs are administered in repeated doses at fixed intervals or through continuous...
Other Nuclides: 31P, 19F, 15N NMR
While fluorine-19 and phosphorous-31 have high natural abundances (100%) and positive gyromagnetic ratios, nitrogen-15 has a low natural abundance and a negative gyromagnetic ratio. However, nitrogen-15 is still preferred over nitrogen-14 (which has a...
Steady Flow of a Fluid Stream
During this process, the momentum of the fluid within the control volume remains constant over the time interval dt. By applying the...
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...