Related Experiment Video
Updated: Jan 24, 2026

Application of a New Mesh Fixation Method in Laparoscopic Incisional Hernia Repair
Published on: December 23, 2022
Accuracy of the ultrasound examination in patients with inguinal hernia
Bárbara Henriqueta Ferreira Duarte1, Ana Paula Marconi Iamarino2, Silvio Gabor3
1Universidade Santo Amaro, Serviço de Cirurgia Geral, São Paulo, SP, Brasil.
Objective:
to evaluate the accuracy of ultrasonography in the diagnosis of inguinal hernia in the preoperative period of patients submitted to inguinal herniorrhaphy.
Methods:
we conducted a retrospective, descriptive, analytical study, based on data obtained from the charts of patients submitted to inguinal herniorrhaphy between January 2016 and December 2017 and who underwent ultrasonography in the preoperative period. The sample consisted of 232 patients, and we compared the results of the ultrasonography with the complaints, physical examination and intraoperative findings.
Results:
ultrasonography was in agreement with inguinal hernia complaint in 52% of patients (p=0.019). There was a disagreement between the percentage of patients who presented a hernia at the physical examination not confirmed by the ultrasound examination (28.57%) and the percentage of hernias identified only by the complementary examination (8.93%), with statistical significance (p=0.0291). When comparing the ultrasound findings with the intraoperative ones, 32.70% of patients presenting with hernia had normal ultrasonography, with statistical significance for discordance (p=0.001).
Conclusion:
ultrasound was an unreliable method to help diagnosis in dubious cases of inguinal hernia, and dispensable when the diagnosis was confirmed by typical complaints and compatible physical examination.
More Related Videos
Related Concept Videos
Improving Translational Accuracy
Improving Translational Accuracy
Uncertainty in Measurement: Accuracy and Precision
Accuracy and Precision
Accuracy, limits, and approximation
Accuracy is defined as the closeness of the measured value to the true or actual value. In engineering mechanics, repeated measurements are taken during theoretical or experimental analyses to ensure that the result is precise and accurate.
The accuracy of any solution is based on the...
Accuracy and Errors in Hypothesis Testing
In hypothesis testing, the probability of making a Type I error, denoted as α, is commonly set at 0.05. This significance level indicates a 5%...