Related Experiment Video
Updated: Jan 24, 2026

Experimental System of Solar Adsorption Refrigeration with Concentrated Collector
Published on: October 18, 2017
Rates of adsorption and desorption: Entropic contributions and errors due to mean-field approximations
1Department of Chemical Engineering, Indian Institute of Technology, Kanpur, Uttar Pradesh 208016, India.
Abstract:
We have performed exact classical rate calculations to compute adsorption and desorption rate constants with a model representative of a real system. We compute the desorption rate using transition-state theory by taking the dividing-surface far from the surface of the solid. We find that using a mean-field assumption, i.e., applying potential of mean force to transition state theory, could lead to two orders-of-magnitude errors in the rate constant owing to large fluctuations in the desorption barrier. Furthermore, we compute the adsorption rate by including a dynamical factor which reflects the probability of sticking to the solid surface. We find that the sticking probability is highly sensitive to the coverage. Also, we find that the adsorption rate computed from the mean-field assumption is not very different from the exact adsorption rate. We also compute entropic contribution to desorption rates and compare it to that obtained from two limiting models of adsorption-2D ideal gas and 2D ideal lattice gas. We show that at high temperatures (700 K), the entropic contribution to desorption rates computed from the exact calculations is very close to that obtained from the 2D ideal gas model. However, for lower to intermediate temperatures from 200 K to 500 K, the entropic contributions cover a wide range which lies in between the two limiting models and could lead to over two-orders-of-magnitude errors in the rate coefficient.
More Related Videos
Related Concept Videos
Linearization and Approximation
Application of Linearization and Approximation
Accuracy, limits, and approximation
Accuracy is defined as the closeness of the measured value to the true or actual value. In engineering mechanics, repeated measurements are taken during theoretical or experimental analyses to ensure that the result is precise and accurate.
The accuracy of any solution is based on the...
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Fundamental Attribution Error
Analyte Adsorption and Distribution

