Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
The accuracy of a 2D video-based lifting monitor
Xuan Wang1, Yu Hen Hu1, Ming-Lun Lu2
1a Department of Electrical and Computer Engineering , University of Wisconsin-Madison , Madison , WI , USA.
Abstract:
A widely used risk prediction tool, the revised NIOSH lifting equation (RNLE), provides the recommended weight limit (RWL), but is limited by analyst subjectivity, experience, and resources. This paper describes a robust, non-intrusive, straightforward approach to automatically extract spatial and temporal factors necessary for the RNLE using a single video camera in the sagittal plane. The participant's silhouette is segmented by motion information and the novel use of a ghosting effect provides accurate detection of lifting instances, and hand and feet location prediction. Laboratory tests using 6 participants, each performing 36 lifts, showed that a nominal 640 pixel × 480 pixel 2D video, in comparison to 3D motion capture, provided RWL estimations within 0.2 kg (SD = 1.0 kg). The linear regression between the video and 3D tracking RWL was R2 = 0.96 (slope = 1.0, intercept = 0.2 kg). Since low definition video was used in order to synchronise with motion capture, better performance is anticipated using high definition video. Practitioner's summary: An algorithm for automatically calculating the revised NIOSH lifting equation using a single video camera was evaluated in comparison to laboratory 3D motion capture. The results indicate that this method has suitable accuracy for practical use and may be, particularly, useful when multiple lifts are evaluated. Abbreviations: 2D: Two-dimensional; 3D: Three-dimensional; ACGIH: American Conference of Governmental Industrial Hygienists; AM: asymmetric multiplier; BOL: beginning of lift; CM: coupling multiplier; DM: distance multiplier; EOL: end of lift; FIRWL: frequency independent recommended weight limit; FM: frequency multiplier; H: horizontal distance; HM: horizontal multiplier; IMU: inertial measurement unit; ISO: International Organization for Standardization; LC: load constant; NIOSH: National Institute for Occupational Safety and Health; RGB: red, green, blue; RGB-D: red, green, blue - depth; RNLE: revised NIOSH lifting equation; RWL: recommended weight limit; SD: standard deviation; TLV: threshold limit value; VM: vertical multiplier; V: vertical distance.
Related Concept Videos
Lift
Improving Translational Accuracy
Improving Translational Accuracy
Uncertainty in Measurement: Accuracy and Precision
Accuracy and Precision
Accuracy, limits, and approximation
Accuracy is defined as the closeness of the measured value to the true or actual value. In engineering mechanics, repeated measurements are taken during theoretical or experimental analyses to ensure that the result is precise and accurate.
The accuracy of any solution is based on the...