Related Experiment Video
Updated: Jan 24, 2026

Clinical Imaging of Microwave Mammography
Published on: November 14, 2025
Comparison of Contrast-Enhanced Mammography With Conventional Digital Mammography in Breast Cancer Screening: A Pilot
Geunwon Kim1, Jordana Phillips1, Elodia Cole2
1Beth Israel Deaconess Medical Center, Boston, Massachusetts.
Purpose:
To perform a pilot evaluation of contrast-enhanced mammography (CEM) for screening to determine whether it can improve accuracy and reader confidence in diagnosis.
Methods And Materials:
This institutional review board-approved reader study was comprised of 64 de-identified CEM cases acquired from December 1, 2014, to June 7, 2016, including 48 negative, 5 biopsy-proven benign, and 11 biopsy-proven malignancies. Negative cases were followed for at least 2 years without evidence of cancer. Ten breast imagers of varying experience first rated the low-energy (LE) mammogram and then the CEM examination using BI-RADS categories and a 5-point Likert scale for confidence in diagnosis.
Results:
There were 635 out a total possible 640 complete reader interpretations included in this analysis. The remaining five incomplete interpretations were excluded. Median sensitivity and specificity improved with the addition of CEM (sensitivity: 0.86 [95% confidence interval {CI}: 0.74-0.95] versus 1 [95% CI: 0.83-1.00], specificity: 0.85 [95% CI: 0.64-0.94] versus 0.88 [95% CI: 0.80-0.92]). Individual receiver operating characteristic curves showed significant improvement with CEM (mean area under the curve increase = 0.056 [95% CI: 0.015-0.097], P = .002). The addition of CEM significantly improved average confidence in 5 of 10 readers when compared with LE (P < .0001) and improved pooled confidence across all tissue density categories, except the almost entirely fatty category. There was a trend toward improved confidence with increasing tissue density with CEM. Degree of background parenchymal enhancement did not affect readers' level of improvement in confidence when interpreting CEM.
Summary:
CEM improved reader performance and confidence compared with viewing only LE, suggesting a role for CEM in breast cancer screening for which larger trials are warranted.
Related Concept Videos
Pilot and Numeric Relaying
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Sign Convention
The normal force acts perpendicular to the beam's cross-section and can...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Enolate Mechanism Conventions
Mouse Models of Cancer Study
The development of transgenic, knockout, and knock-in mice has led to an exponential increase in their use as model organisms in research,...