Randomized comparison between epidural waveform analysis through the needle versus the catheter for thoracic epidural
Amornrat Tangjitbampenbun1, Sebastián Layera2, Vanlapa Arnuntasupakul1
1Anesthesia, Mahidol University Faculty of Medicine Ramathibodi Hospital, Bangkok, Thailand.
Epidural waveform analysis (EWA) using the needle (EWA-N) or catheter (EWA-C) showed similar performance times and efficacy in thoracic epidural blocks. Both methods confirmed correct needle placement for anesthesia.
Area of Science:
- Anesthesiology
- Pain Management
- Neurosurgery
Background:
- Epidural waveform analysis (EWA) confirms correct epidural needle or catheter tip placement via pulsatile waveforms.
- EWA can be performed through the needle (EWA-N) or the catheter (EWA-C).
Purpose of the Study:
- To compare the performance time and efficacy of EWA-N versus EWA-C in thoracic epidural blocks.
- To test the hypothesis that EWA-N results in a shorter performance time than EWA-C.
Main Methods:
- A randomized trial involving 120 patients undergoing thoracic epidural blocks.
- Patients were randomized to either EWA-N or EWA-C for loss of resistance confirmation.
- Performance time, block success rate, postoperative pain, and local anesthetic consumption were recorded.
Main Results:
- No significant differences were observed between EWA-N and EWA-C groups in performance time.
- Success rates, postoperative pain scores, and local anesthetic requirements were comparable between the two groups.
Conclusions:
- Epidural waveform analysis is equally efficient and effective whether performed through the needle or the catheter.
- Both EWA-N and EWA-C are reliable methods for confirming epidural placement and ensuring successful postoperative analgesia.
More Related Videos
Related Concept Videos
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
Effective Value of a Periodic Waveform
The effective value of a periodic current represents the direct current (DC) that conveys the same average power to a resistor as the periodic current itself. This concept is crucial when assessing AC circuits. To determine the...
Thoracic Aorta
Random Error
Random Variables
Uppercase letters such as X or Y denote a random variable. Lowercase letters like x or y denote the value of a random variable. If X is a random variable, then X is written in words, and x is given as a number.
For example, let X = the...