Model Validation Study of Carbon Monoxide Transport due to Portable Electric Generator Operation in an Attached
Steven J Emmerich1, W Stuart Dols1
1Indoor Air Quality and Ventilation Group, Energy and Environment Division, Engineering Laboratory, National Institute of Standards and Technology, 100 Bureau Drive, Stop 8633, Gaithersburg, MD 20899, USA.
Abstract:
A series of tests was conducted to characterize the indoor CO concentrations resulting from portable electric generators operating in the attached garage of a test house under various use and environmental conditions. An extensive model validation effort using the multizone airflow and indoor air quality (IAQ) model CONTAM was carried out using the data from seven tests with a generator operating in the attached garage to compare predicted CO concentrations with measured values. The agreement between the measurements and predictions of the O2 concentrations in the garage and the average CO concentration for the house zones was excellent for the dataset as a whole. The agreement was somewhat worse for the garage CO concentrations. Overall, the house zone average and garage CO concentration predictions and measurements were within about 20 % and 30 % respectively when averaged over all cases.
Related Concept Videos
Carbon Dioxide Transport in the Blood
Forms of CO2 Transport
1. Dissolved in plasma: A small percentage (7-10%) of CO2 is transported and dissolved directly in the plasma.
2. Carbaminohemoglobin: Just over 20% of CO2 is chemically bound to...
Electric Generator: Alternator
The magnetic flux passing through the coil varies sinusoidally as the loop rotates inside the magnetic field. This...
Attachment
Reliability and Validity
Electron Transport Chains
The ETC is comprised of...
Attachment Styles