Related Experiment Video
Updated: Jan 24, 2026

Automation of Mode Locking in a Nonlinear Polarization Rotation Fiber Laser through Output Polarization Measurements
Published on: February 28, 2016
Evaluating the Laser Output of the Micropulse P3 Laser Delivery Device Following Repeated Use
Katherine Lun1,2, Maya E Suwandono1, Victor Koh1,2
1Department of Ophthalmology, National University Hospital.
Precis:
Repeated use of the Micropulse P3 (MP3) probe during micropulse transscleral cyclophotocoagulation is associated with an increase in laser output over time.
Purpose:
The purpose of this study was to examine the laser efficacy of the MP3 probe following repeated use.
Methods:
This was an observational study carried out using Cyclo G6 Glaucoma Laser System with 6 MP3 laser delivery probes. Each probe was fired for 100 seconds, every 10 minutes until the probe was deactivated. The laser output was measured using a laser power meter. Maximum observed laser power output was also noted.
Results:
All probes were deactivated after 90 minutes (9 cycles) of use. Mean laser output of all 6 probes was determined, and results suggested an increase in output with time. When examining the differences in total laser output for each cycle, no significant differences were observed for the first 4 cycles, but not for the remaining 5 cycles, wherein the increased laser outputs were found to be significantly different from baseline (cycle 1).
Conclusion:
Findings suggest a possible increase in laser output with repeated use, especially after 4 cycles, and clinicians need to be cautious if they intend to use the probes repeatedly.
Related Concept Videos
Matrix-Assisted Laser Desorption Ionization (MALDI)
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Regulation of Water Output