Corneal deformation amplitude analysis for keratoconus detection through compensation for intraocular pressure and
Edileuza Leão1, Tsang Ing Ren2, João M Lyra3
1Centro de Informática (CIn) - Universidade Federal de Pernambuco (UFPE) - v. Jornalista Aníbal Fernandes, Cidade Universitária, 50740-560, Recife, PE, Brazil; Universidade Estadual de Ciências da Saúde de Alagoas (UNCISAL), Brazil; Brazilian Study Group of Artificial Intelligence and Corneal Analysis (BrAIn), Brazil.
Background:
The Corvis ST provides measurements of intraocular pressure (IOP) and a biomechanically-corrected IOP (bIOP). IOP influences corneal deflection amplitude (DA), which may affect the diagnosis of keratoconus. Compensating for IOP in DA values may improve the detection of keratoconus.
Methods:
195 healthy eyes and 136 eyes with keratoconus were included for developing different approaches to distinguish normal and keratoconic corneas using attribute selection and discriminant function. The IOP compensation is proposed by dividing the DA by the IOP values. The first approaches include DA compensated for either IOP or bIOP and other parameters from the deformation corneal response (DCR). Another approach integrated the horizontal corneal thickness profile (HCTP). The best classifiers developed were applied in a validation database of 156 healthy eyes and 87 eyes with keratoconus. Results were compared with the current Corvis Biomechanical Index (CBI).
Results:
The best biomechanical approach used the DA values compensated by IOP (Approach 2) using a linear discriminant function and reached AUC 0.954, with a sensitivity of 88.2% and a specificity of 97.4%. When thickness horizontal profile data was integrated (Approach 4), the best function was the diagquadratic, resulting in an AUC of 0.960, with a sensitivity of 89.7% and a specificity of 96.4%. There was no significant difference in the results between approaches 2 and 4 with the CBI in the training and validation databases.
Conclusions:
By compensating for the IOP, and with the horizontal thickness profile included or excluded, it was possible to generate a classifier based only on biomechanical information with a similar result to the CBI.
More Related Videos
06:55Scanning Light Scattering Profiler SLPS Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses
Published on: June 6, 2017
09:01Gain-compensation Methodology for a Sinusoidal Scan of a Galvanometer Mirror in Proportional-Integral-Differential Control Using Pre-emphasis Techniques
Published on: April 4, 2017
Related Concept Videos
Dosage Compensation
In addition to sexual development, the X chromosome has genes involved in autosomal functions such as brain development and the immune system. Therefore, males and females with distinct numbers of X chromosomes will...
Compensation Mechanisms
Respiratory Compensation
This mechanism addresses metabolic-induced pH imbalances by adjusting breathing rates. Respiratory compensation begins within minutes of detecting a pH...
Plastic Deformations
Plastic Deformations
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Introduction to Horizontal Curves