Corneal sterile infiltration induced by topical use of ocular hypotensive agent
Yusuke Manabe1, Akira Sawada1, Kiyofumi Mochizuki1
1Department of Ophthalmology, Gifu University Graduate School of Medicine, Gifu, Japan.
Purpose:
To report two cases with corneal sterile infiltration presumably due to topical ocular hypotensive agent.
Method:
Case report.
Results:
Case 1: A 65-year-old man presented with corneal opacity and neovascularization in his left eye. A diagnosis of glaucoma was made 2 years previously, and anti-glaucoma agents were prescribed (brimonidine tartrate, ripasudil hydrochloride hydrate, and brinzolamide) for both eyes. Case 2: A 75-year-old woman noticed corneal opacity in the left eye. A diagnosis of glaucoma was made 35 years previously, and anti-glaucoma agents were prescribed (brimonidine tartrate, 1% dorzolamide, and bimatoprost) for both eyes. In both cases, ocular examination revealed follicular conjunctivitis and blepharitis in both eyes, and corneal sterile infiltration with neovascularization in the left eyes. The three topical drugs were discontinued and replaced with 0.1% fluorometholone. Both the blepharitis and corneal sterile infiltration improved thereafter, although corneal opacity remained across the stromal layer.
Conclusion:
We encountered two cases of corneal and conjunctival complications that were suspected as side effects after brimonidine eye drop use. Special care should be taken to observe the condition of ocular surface when topical brimonidine is administered.
Related Concept Videos
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Subviral Agents
Air-entraining Agents
Masking and Demasking Agents
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on...