Related Experiment Video
Updated: Jan 24, 2026

Genotyping of Staphylococcus aureus by Ribosomal Spacer PCR RS-PCR
Published on: November 4, 2016
Composite or aseptic quarter milk samples: Sensitivity and specificity of PCR and bacterial culture of Staphylococcus
N Toft1, T Halasa2, S S Nielsen3
1Division for Diagnostics and Scientific Advice, National Veterinary Institute, Technical University of Denmark, 2800 Kgs. Lyngby, Denmark.
Abstract:
Bacterial culture (BC) and quantitative polymerase chain reaction (qPCR) are widely used as diagnostic tests for pathogens causing intra-mammary infections (IMI) and it is therefore important to evaluate their performance to optimize pathogen detection. However, with no reference standard, their sensitivity (Se) and specificity (Sp) are unknown. Furthermore, the Se and Sp can differ between quarter samples and composite samples, both of which can be used to test for IMI. Latent class analysis (LCA) offers a method for estimating the Se and Sp of two tests on the same population, but to our knowledge this has not yet been applied to qPCR and BC for the detection of Staph. aureus in both composite and aseptically collected quarter milk samples. This allows for a performance evaluation of not only the two diagnostic methods, but also the two different samples -both cow and quarter level. In this study, we used Bayesian LCA on a dataset from one sampling day at a Danish dairy herd to estimate the Se and Sp for detecting Staph. aureus at cow and quarter level. We used Ct cut-offs of 32 and 37 cycles for the qPCR. When using a cut-off of 37 cycles, the estimated Se and Sp for BC were 62.2% and 90.5% at cow level, and 90.7% and 93.5% at quarter level, respectively. Similarly, the estimated Se and Sp for qPCR at cow level were 82.7% and 84.1%, respectively, and 80.0% and 96.8% at quarter level. Sp was therefore higher for both BC and qPCR at quarter level. Se was also highest for BC at quarter level, but the opposite was true for qPCR. The same pattern was found using a Ct cut-off at 32 cycles, but with different estimates. The results show that qPCR with a Ct cut-off at 37 had a higher Se than BC for composite DHI samples and it is therefore more suitable as a routine screening test for Staph. aureus. However, BC on quarter samples gave the highest Se and Sp and should therefore be used for confirmatory testing.
More Related Videos
09:03Multiplex PCR Assay for Typing of Staphylococcal Cassette Chromosome Mec Types I to V in Methicillin-resistant Staphylococcus aureus
Published on: September 5, 2013
08:08The Use of Drip Flow and Rotating Disk Reactors for Staphylococcus aureus Biofilm Analysis
Published on: December 27, 2010
Related Concept Videos
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Sputum Studies II: Culture and Sensitivity
Sputum culture and sensitivity is a medical procedure used to diagnose bacterial infections in the respiratory tract and select the most appropriate antibiotics for treatment. This process involves analyzing sputum samples of thick and opaque secretions produced in the lungs and airways. These samples are collected from patients and then sent to the laboratory for analysis.
The test can identify various pathogens responsible for respiratory infections, including Streptococcus,...
Classifying Matter by Composition
According to its composition, the matter can be classified into two broad categories — pure substances and mixtures.
A pure substance is a form of matter that has a constant composition throughout with uniform properties. For example, any sample of sucrose has the same composition and same physical properties, such as melting point, color, and sweetness, regardless of the source from which it is isolated.
A mixture is composed of two or...
Solution Composition During Acid/Base Titrations
The α0 and α1 values...
PCR
Urine Studies II: Urine Culture and Sensitivity Test