Accuracy of Doppler blood pressure measurement in continuous-flow left ventricular assist device patients
Song Li1, Jennifer A Beckman1, Nathan G Welch2
1Division of Cardiology, Department of Medicine, University of Washington, Seattle, WA, 98195, USA.
Insights
Accurate blood pressure (BP) measurement is crucial for continuous-flow ventricular assist device (CF-VAD) patients. Doppler opening pressure offers a reliable non-invasive method for BP assessment in these individuals.
Area of Science:
- Cardiovascular Medicine
- Biomedical Engineering
Background:
- Accurate blood pressure (BP) monitoring is critical for managing patients with continuous-flow ventricular assist devices (CF-VADs) to mitigate risks such as stroke.
- Current non-invasive BP measurement methods may lack accuracy in CF-VAD populations.
Purpose of the Study:
- To evaluate the accuracy of the Doppler opening pressure method for BP measurement in CF-VAD patients.
- To compare Doppler opening pressure accuracy against the gold standard invasive arterial line method.
Main Methods:
- A longitudinal cohort study involving HeartMate II and HVAD patients.
- Simultaneous measurement of arterial line BP and Doppler opening pressure.
- Analysis of correlation and agreement between methods, including the impact of arterial pulsatility.
Main Results:
- 1933 paired readings from 154 CF-VAD patients were analyzed.
- Doppler opening pressure showed good correlation with invasive mean arterial pressure (r=0.742, P<0.0001).
- The method more accurately approximated mean arterial pressure (mean error 2.4 mmHg) than systolic BP (mean error -8.4 mmHg), with no significant effect from arterial pulsatility.
Conclusions:
- Doppler opening pressure demonstrates good accuracy for BP measurement in CF-VAD patients.
- This non-invasive technique is a viable alternative to invasive monitoring.
- Doppler opening pressure is recommended as the standard non-invasive BP measurement in CF-VAD patients.
Aims:
Accurate blood pressure (BP) measurement in continuous-flow ventricular assist device (CF-VAD) patients is imperative to reduce stroke risk. This study assesses the accuracy of the Doppler opening pressure method compared with the gold standard arterial line method in CF-VAD patients.
Methods And Results:
In a longitudinal cohort of HeartMate II and HVAD patients, arterial line BP and simultaneously measured Doppler opening pressure were obtained. Overall correlation, agreement between Doppler opening pressure and arterial line mean vs. systolic pressure, and the effect of arterial pulsatility on the accuracy of Doppler opening pressure were analysed. A total of 1933 pairs of Doppler opening pressure and arterial line pressure readings within 1 min of each other were identified in 154 patients (20% women, mean age 55 ± 15, 50% HeartMate II and 50% HVAD). Doppler opening pressure had good correlation with invasive mean arterial pressure (r = 0.742, P < 0.0001) and more closely approximated mean than systolic BP (mean error 2.4 vs. -8.4 mmHg). Arterial pulsatility did not have a clinically significant effect on the accuracy of the Doppler opening pressure method.
Conclusions:
Doppler opening pressure should be the standard non-invasive method of BP measurement in CF-VAD patients.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Measurement of Blood Pressure
Uncertainty in Measurement: Accuracy and Precision
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer