Improvement in diagnostic quality of structural and angiographic MRI of the brain using motion correction with

Mads Andersen1,2, Isabella M Björkman-Burtscher3,4,5, Anouk Marsman1

  • 1Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Hvidovre, Hvidovre, Denmark.

Plos One
|May 18, 2019
PubMed
Abstract

Insights

The iMOCO system significantly improves diagnostic image quality in magnetic resonance (MR) brain imaging affected by subject movement. This prospective motion correction technology recovers usable diagnostic information from otherwise unusable scans.

Area of Science:

  • Medical Imaging
  • Neuroimaging
  • Magnetic Resonance Imaging

Background:

  • Subject movement during magnetic resonance (MR) brain imaging causes severe artifacts, compromising diagnostic image quality.
  • Prospective motion correction systems aim to mitigate these artifacts in real-time.

Purpose of the Study:

  • To evaluate the diagnostic image quality of T1-weighted, T2-weighted, and time-of-flight (TOF) angiographic MR sequences using a flexible, navigator-based prospective motion correction system (iMOCO).

Main Methods:

  • Five healthy volunteers underwent MR brain scans with and without the iMOCO system activated under various movement scenarios.
  • An experienced neuroradiologist assessed image quality using a four-grade scale, focusing on grey-white matter discrimination, basal ganglia, and small structure/vessel delineation.

Main Results:

  • iMOCO significantly improved general image impression and anatomical grading across T1, T2, and TOF sequences when deliberate motion was present (p<0.01 for most).
  • Non-diagnostic image quality decreased from 91% without iMOCO to 4% with iMOCO in scans with motion.
  • iMOCO showed no negative impact on image quality in scans without deliberate movement.

Conclusions:

  • The iMOCO system substantially enhances MR brain imaging quality in the presence of subject motion.
  • This technology effectively recovers diagnostic information from scans that would otherwise be rendered unusable due to artifacts.

Related Concept Videos

Distance Corrections01:15

Distance Corrections

To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
285
Power Factor Correction01:20

Power Factor Correction

The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
510
Equation of Motion: General Plane motion01:22

Equation of Motion: General Plane motion

In the context of a rigid body's movement within a general plane, it is important to understand that this motion is typically triggered by external forces or couple moments exerted onto it. This principle can be explained through Newton's second law, which stipulates the translational motion of the body's center of mass along each axis.
Moreover, the body's center of mass experiences a rotational effect as a result of these couple moments. This rotation can be articulated as the...
565
NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
1.0K
Quality of Water01:19

Quality of Water

In concrete preparation, the quality of water is paramount as it affects the strength and durability of the concrete. Potable water is usually preferred; however, it must not have excessive sodium or potassium to prevent compromising the concrete's integrity. Water quality is typically evaluated based on impurities such as dissolved solids, chlorides, and sulfates, and its pH value is ideally between 6 and 8. Even slightly acidic natural water may be acceptable unless it contains harmful...
514
Quality Control01:05

Quality Control

Quality control is one of the three cyclical quality assurance activities that help keep a system under statistical control. Typical quality control activities include creating quality control charts, conducting proficiency testing, and documenting and archiving results.
Quality control helps track data, visualize trends, and identify variations, making it easier to detect deviations that may affect the accuracy of an analysis. One way to do this is by generating a quality control chart, which...
1.4K