Background And Purpose:
For the assessment of cardiovascular blood flow, 2D flow (2D) and 4D flow with a single venc (4D Mono) are established techniques. The objective of this study was to validate a multi-venc 4D flow (4D Multi) sequence for the improved simultaneous assessment of arterial and venous flow in high and low flow conditions and to investigate the scan-rescan reproducibility and inter-observer variability of the novel sequence.
Methods:
Eleven volunteers with no known heart condition (female: 6, mean age: 25.8 ± 9.1 years) and two patients with a Fontan circulation were examined using phase-contrast 2D and 4D flow MRI. Stroke volumes, maximum velocities, net flow curves and internal consistency were measured and compared between 2D, 4D Mono and 4D Multi. Additionally, scan-rescan and inter-observer variabilities were analyzed. Finally, qualitative visualization comparisons were performed.
Results:
Bland-Altman analysis show a higher agreement in stroke volumes between 4D Multi and 2D (7 ± 11%) than 4D Mono and 2D (11 ± 24%). 4D Multi is more accurate than 4D Mono in measuring time-resolved net flow throughout the cardiac cycle and qualitative blood flow visualization of 4D Multi is more accurate in visualizing flow patterns revealing more details and less artifacts than 4D Mono. Scan-rescan reproducibility is higher in 4D Multi (-0.04 ± 4.5 ml) than 2D (2.1 ± 7.3 ml) and inter-observer variability is low in both techniques (2D: -0.4 ± 3.4 ml and 4D Multi: 0.4 ± 3.5 ml). Internal consistency was improved in volunteers and patients when using 4D Multi as compared to 4D Mono.
Conclusion:
4D Multi offers a comprehensive way to accurately quantify flow in arteries and veins both in high and low flow situations and to visualize detailed flow patterns. This technique is readily applicable in the clinical setting and has the potential to be beneficial in the clinical assessment of valvular and congenital heart diseases.
More Related Videos
11:16In vitro Assessment of Aortic Regurgitation Using Four-Dimensional Flow Magnetic Resonance Imaging
Published on: February 25, 2022
08:35Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
Related Concept Videos
Multi-species Conserved Sequences
Although the genome of each species varies greatly from each other, a few sequences are highly conserved. Such conserved...
Uncertainty in Measurement: Accuracy and Precision
Accuracy and Precision
Cis-regulatory Sequences
Gene Flow
Multi-input and Multi-variable systems
In the absence of...