Comparison of 18F-florbetaben quantification results using the standard Centiloid, MR-based, and MR-less CapAIBL®
Vincent Doré1, Santiago Bullich2, Christopher C Rowe3
1Department of Molecular Imaging & Therapy, Austin Health, Melbourne, VIC, Australia; CSIRO Health and Biosecurity Flagship: The Australian e-Health Research Centre, Brisbane, QLD, Australia.
Introduction:
18F-florbetaben is currently approved for the visual rule out of β-amyloid (Aβ) pathology. It is also used for recruitment and as an outcome measure in therapeutic trials, requiring accurate and reproducible quantification of Aβ burden in the brain.
Methods:
Data from eighty-eight subjects (52 male subjects, aged 79.8 ± 10.6 years) who underwent antemortem 18F-florbetaben positron emission tomography scan and magnetic resonance imaging less than a year before neuropathological assessment at autopsy were evaluated. Image analysis was performed using the standard Centiloid (CL) statistical parametric mapping approach and CapAIBL®. Imaging results were compared against autopsy data.
Results:
Against combined Bielschowsky silver staining and immunohistochemistry histopathological scores, statistical parametric mapping had 96% sensitivity, 96% specificity, and 95% accuracy, whereas magnetic resonance-less CapAIBL standardized uptake value ratioWhole Cerebellum had 94% sensitivity, 96% specificity, and 95% accuracy. Based on the combined histopathological scores, a CL threshold band of 19 ± 7 CL was determined.
Discussion:
Quantification of 18F-florbetaben positron emission tomography scans using magnetic resonance-based and magnetic resonance-less CapAIBL® approaches showed high agreement, establishing a pathology-based threshold in CL.
More Related Videos
09:58Quantitative Immunoblotting of Cell Lines as a Standard to Validate Immunofluorescence for Quantifying Biomarker Proteins in Routine Tissue Samples
Published on: January 7, 2019
14:25Synthesis of a Deuterated Standard for the Quantification of 2-Arachidonoylglycerol in Caenorhabditis elegans
Published on: September 21, 2019
Related Concept Videos
Reliability and Validity
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Measurement: Standard Units
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...
Data Validation
Key parameters for method validation include: