Related Experiment Video
Updated: Jan 24, 2026

Anatomically Realistic Neonatal Heart Model for Use in Neonatal Patient Simulators
Published on: February 5, 2019
Impact of a mobile application for heart rate assessment in simulated neonatal resuscitation: a randomised controlled
Francesco Cavallin1, Marco Binotti2, Pierluigi L Ingrassia3
1Independent Statistician, Solagna, Italy.
Background:
Clinical assessment of newborn heart rate (HR) at birth has been reported to be inaccurate. NeoTapAdvancedSupport (NeoTapAS) is a free-of-charge mobile application that showed good accuracy in HR estimation. This study aimed to evaluate the impact of NeoTapAS on timing of HR communication and resuscitation interventions.
Methods:
This was a randomised controlled cross-over (AB/BA) study evaluating HR assessment using auscultation plus NeoTapAS compared with auscultation plus mental computation in a high-fidelity simulated newborn resuscitation scenario. Twenty teams each including three paediatric residents were randomly assigned to AB or BA arms. The primary outcome was the timing of the first HR communication. Secondary outcomes included the timing of the following four HR communications and the timing of resuscitation interventions (positive pressure ventilation, chest compressions, intubation and administration of first dose of epinephrine).
Results:
NeoTapAS reduced the time to the first HR communication (mean difference -13 s, 95% CI -23 to -4; p=0.009), and the time of initiation of chest compressions (mean difference -68 s, 95% CI -116 to -18; p=0.01) and administration of epinephrine (mean difference -76 s, 95% CI -115 to -37; p=0.0004) compared with mental computation.
Conclusions:
In a neonatal resuscitation simulated scenario, NeoTapAS reduced the time to the first HR communication and the time of initiation of chest compressions and administration of epinephrine compared with mental computation. This app can be especially useful in settings with limited availability of monitoring equipment, but further studies in clinical scenarios are warranted.
Trial Registration Number:
NCT03730025.
More Related Videos
07:49Author Spotlight: Investigating HR-Dependent Cardiac Function in Mouse Models Through a Novel Atrial-Pacing Approach
Published on: July 21, 2023
10:55A Piglet Perinatal Asphyxia Model to Study Cardiac Injury and Hemodynamics after Cardiac Arrest, Resuscitation, and the Return of Spontaneous Circulation
Published on: January 13, 2023
Related Concept Videos
Regulation of Heart Rates
The SNS increases heart rate through the release of norepinephrine and epinephrine, which act on beta-1 adrenergic receptors in the heart. This action increases the rate of depolarization in the sinoatrial (SA) node, the heart's...
Application of Rates of Change
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Control Systems: Applications
In modern vehicles, control systems manage various functions to enhance performance and safety. The steering wheel and accelerator are primary inputs in a car's control system. The...
Drug Control Governance: Regulatory Bodies and Their Impact
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation: