Related Experiment Video
Updated: Jan 24, 2026

A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
Published on: June 2, 2015
Non-sedated functional imaging based on deep synchronization of PROPELLER MRI and NIRS
Liang Deng1, Juntian Zhang2, Jitao Chen1
1Beijing National Laboratory for Molecular Sciences, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, China.
Background And Objective:
Periodically rotated overlapping parallel lines with enhanced reconstruction-echo planar imaging (PROPELLER-EPI) is a promising technique for non-sedated functional imaging due to its unique advantage of motion correction. However, its multiple-blades sampling blood-oxygen-level dependent (BOLD) signal leads to low sampling rate and aliasing of higher frequency physiological signal components such as the cardiac pulsation.
Methods:
In this study, we use near infrared spectroscopy (NIRS) synchronized with pulse sequences of PROPELLER-EPI, utilizing the fact that the optical sensing speed is inherently high. NIRS measures changes of oxyhemoglobin and deoxyhemoglobin to identify the transient states of on-BOLD and off-BOLD, and then labels each blade by temporal co-registration. The labeled blades from multiple epochs of a functional experiment are then used for the k-space data combination and subsequent image reconstruction. An eigenfunction model is proposed for temporal co-registration and to quantify the temporal resolution of the hemodynamic response.
Result:
The experiment of NIRS labeled PROPELLER-EPI was carried out with the optical sampling rate of 10 Hz and the magnetic pulses repetition time of 1000 ms, and the temporal resolution is 20 times better than that of the state-of-the-art sliding-window PROPELLER-EPI. We compared the functional imaging results against the conventional magnetic resonance echo planar imaging-measured activity and achieved an accuracy of 0.9.
Conclusions:
Using the synchronization of NIRS, the proposed imaging scheme provides an effective way to implement PROPELLER-EPI, which features motion free, high SNR, and enhanced spatial-temporal resolution.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Sedatives and Hypnotics: Overview
Sedative-hypnotics are categorized into barbiturates, benzodiazepines (BZDs), and non-benzodiazepines or Z-drugs. These drugs work by suppressing central nervous system activity, and this suppression is dose-dependent. Older sedative medications, like barbiturates, follow a linear curve in...
Sedatives and Hypnotics Drugs: Barbiturates
Sedatives and Hypnotics Drugs: Benzodiazepines
Benzodiazepines work by enhancing the effects of the inhibitory neurotransmitter GABA. They bind to the GABAA receptor, increasing its affinity for GABA, which opens chloride...
Sedatives and Hypnotics Drugs: Miscellaneous Agents
Melatonin congeners like ramelteon (Rozerem) and tasimelteon (Hetlioz) selectively bind to melatonin receptors (MT1 and MT2) and thus mimic the actions of melatonin, a hormone that regulates sleep-wake cycles. Tasimelteon is primarily used for non-24-hour sleep-wake disorder, common in blind patients. They are also used to treat conditions like insomnia...
Simplified Synchronous Machine Model
In this model, each generator is connected to a...

