Related Experiment Video
Updated: Jan 24, 2026

Preparation and Characterization of Nanoliposomes for the Entrapment of Bioactive Hydrophilic Globular Proteins
Published on: August 31, 2019
Computer-aided gradient optimization of hydrophilic interaction liquid chromatographic separations of intact proteins
Guusje van Schaick1, Bob W J Pirok2, Rob Haselberg3
1Division of Bioanalytical Chemistry, Amsterdam Institute for Molecules, Medicines and Systems, Vrije Universiteit Amsterdam, de Boelelaan 1085, 1081 HV Amsterdam, The Netherlands.
Abstract:
Protein glycosylation is one of the most common and critical post-translational modification, which results from covalent attachment of carbohydrates to protein backbones. Glycosylation affects the physicochemical properties of proteins and potentially their function. Therefore it is important to establish analytical methods which can resolve glycoforms of glycoproteins. Recently, hydrophilic-interaction liquid chromatography (HILIC)-mass spectrometry has demonstrated to be a useful tool for the efficient separation and characterization of intact protein glycoforms. In particular, amide-based stationary phases in combination with acetonitrile-water gradients containing ion-pairing agents, have been used for the characterization of glycoproteins. However, finding the optimum gradient conditions for glycoform resolution can be quite tedious as shallow gradients (small decrease of acetonitrile percentage in the elution solvent over a long time) are required. In the present study, the retention mechanism and peak capacity of HILIC for non-glycosylated and glycosylated proteins were investigated and compared to reversed-phase liquid chromatography (RPLC). For both LC modes, ln k vs. φ plots of a series of test proteins were calculated using linear solvent strength (LSS) analysis. For RPLC, the plots were spread over a wider φ range than for HILIC, suggesting that HILIC methods require shallower gradients to resolve intact proteins. Next, the usefulness of computer-aided method development for the optimization of the separation of intact glycoform by HILIC was examined. Five retention models including LSS, adsorption, and mixed-mode, were tested to describe and predict glycoprotein retention under gradient conditions. The adsorption model appeared most suited and was applied to the gradient prediction for the separation of the glycoforms of six glycoproteins (Ides-digested trastuzumab, alpha-acid glycoprotein, ovalbumin, fetuin and thyroglobulin) employing the program PIOTR. Based on the results of three scouting gradients, conditions for high-efficiency separations of protein glycoforms varying in the degree and complexity of glycosylation was achieved, thereby significantly reducing the time needed for method optimization.
Related Concept Videos
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Protein and Protein Structure
A protein's shape is critical to its function. For example, an enzyme...
Protein Networks
These interactions can be represented through maps depicting protein-protein interaction networks, represented as nodes and edges. Nodes are circles that are representative of a protein,...
Conjugated Proteins
Nucleoproteins are protein complexes that contain nucleic acids, categorized as deoxyribonucleoproteins (DNPs) or ribonucleoproteins (RNPs) respectively. The nucleosome is a typical example of a DNP where nuclear DNA is associated with histone proteins. The major antigen for the Covid-19 virus SARS-CoV is an RNP that is critical...
What are Proteins?
Electrochemical Gradient and Channel Proteins: An Overview
The electrical gradient: The electrical gradient across cell membranes refers to the difference in electric charge between the inside and outside of a cell. This difference drives the movement of ions towards or away from the cells. For instance, if the inside of the cell is more negatively charged relative to...