Related Experiment Video
Updated: Jan 24, 2026

Author Spotlight: Advancing 3D Modeling for Enhanced Diagnosis and Treatment of Pulmonary Nodules in Early-Stage Lung Cancer
Published on: October 13, 2023
Matching locating holes in multiple plates to record bone position for accurate reconstruction after segmental
1Department of Oral and Maxillofacial Surgery, School and Hospital of Stomatology, Wuhan University, Wuhan, People's Republic of China; The State Key Laboratory Breeding Base of Basic Science of Stomatology (Hubei-MOST) & Key Laboratory of Oral Biomedicine Ministry of Education, School & Hospital of Stomatology, Wuhan University, Wuhan, People's Republic of China.
Abstract:
Segmental defect areas in the mandible can change immediately following osteotomy due to muscular traction, impacting on accurate reconstruction. The purpose of this article is to introduce a new technique based on virtual surgery planning to record the position of the bony parts prior to mandibulectomy, for use in precise mandibular reconstruction after segmental osteotomy. The position information for the bony parts is transferred to a plate with complementary surface contact and locating holes with specific directions and angles. This technique was performed for six patients with segmental defects and the results were compared to those of six previous patients in whom the technique was not utilized. The design of the location holes shortened the average operation time from 406 minutes to 349 minutes (P = 0.033) and decreased the average, maximum, and minimum graft deviation from 1.21 mm to 0.88 mm (P = 0.015), 1.28 mm to 0.99 mm (P = 0.027), and -1.15 mm to -0.77 mm (P = 0.077), respectively. The design of the locating holes in multiple plates shortened the time taken for the bony repositioning step and hence significantly shortened the total operation time. More importantly, it also increased the reconstructive accuracy.
Related Concept Videos
Design Example: Identifying the Locations of Monuments in the Field Using Global Positioning System Device
Sign Test for Matched Pairs
To conduct the sign test, we first calculate the differences in...
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Chromatin Position Affects Gene Expression
Topologically Associated Domains (TADs)
The 3-dimensional positioning of chromatin in the nucleus influences the...
Location and Orientation of the Heart
Data Reporting and Recording

