[Acquisition of Pulmonary Vein and Left Atrium with Trigger Angiography Non-contrast Enhanced MRI in Diastolic Phase]
Tomofumi Misaka1, Takahiro Sakamoto1, Chiharu Yamada1
1Department of Radiology, Kindai University Nara Hospital.
Objective:
The aim of this study was to compare the image quality and the visibility of trigger angiography non-contrast enhanced (TRANCE) in diastolic phase and 3D balanced steady-state free precession (3D SSFP) sequences for the evaluation of pulmonary vein (PV) and left atrium (LA).
Methods:
About 10 volunteers underwent TRANCE and 3D SSFP imaging on 1.5 T MRI. Axial images were reconstructed and regions of interest were positioned on the right superior pulmonary vein (RSPV), right inferior pulmonary vein (RIPV), left superior pulmonary vein (LSPV), left inferior pulmonary vein (LIPV), LA, and left atrial appendage (LAA). Contrast-to-noise ratio (CNR) between each part and muscle were calculated and compared between two sequences. The two observers independently scored the image quality of each image on the basis of PV, LA, and LAA anatomy and contour using a five-point scale, which scores were averaged and compared.
Results:
CNRs on RSPV, RIPV, LSPV, LIPV, LA, and LAA were significantly higher in TRANCE sequence compared with 3D SSFP sequence. On visual assessment, TRANCE showed significantly higher scores in RSPV, RIPV, LSPV, LIPV compared with 3D SSFP sequence.
Conclusions:
TRANCE provides higher image quality in PVs and LA compared with 3D SSFP on 1.5 T MRI. On visual assessment, TRANCE provides better visibility of PVs anatomy and contour compared with 3D SSFP.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Light Acquisition
Phase Diagrams
Phase Transitions
Veins
Structure of Veins:
The structure of veins is specifically designed to assist in the low-pressure transportation of...
Inductance: Single-Phase And Three-Phase Line
Single-Phase Two-Wire Line:
A single-phase line consists of two solid cylindrical conductors, denoted as x and y. Each conductor carries phasor currents ix and iy, respectively. Given that the sum of these currents is...