Low Dose and Low Contrast Medium Coronary CT Angiography Using Dual-Layer Spectral Detector CT
Yan Yi1, Xue-Mei Zhao1, Run-Ze Wu2
1Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College.
Abstract:
The aim of the present study was to investigate the performance of low keV mono-energetic reconstructions in spectral coronary computed tomography angiography (CCTA) using spectral detector CT (SDCT) with reduced contrast media and radiation dose.Sixty patients were randomly assigned to Groups A and B (both n = 30) to undergo CCTA on a dual-layer SDCT with tube voltage 120 kVp and 100 kVp (average tube current: 108.5 and 73.8 mAs, respectively), with contrast media volume of 36 mL used in both groups. The mono-energetic 40-80 keV and conventional 120 kVp images in Group A and conventional 100 kVp images in Group B were reconstructed. Quantitative and qualitative image quality (IQ) were evaluated in the aortic root and distal segments of the coronary arteries.The patient characteristics were not significantly different between the two groups (all P≥ 0.47), nor was the effective radiation dose (1.5 ± 0.3 and 1.4 ± 0.3 mSv, P = 0.20). The quantitative IQ in aorta and coronary arteries of mono-energetic 40-60 keV was superior to conventional 120 kVp and 100 kVp images (all P < 0.05). The noise in spectral images was lower compared to conventional images (all P < 0.01). The subjective IQ score of 40-50 keV images was not significantly different from that of 100 kVp images (P > 0.8).The mono-energetic 40-50 keV reconstructions from spectral CCTA using SDCT provide improved IQ compared to conventional techniques while facilitating reduced radiation dose and contrast media.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
07:54Implantation and Monitoring by PET/CT of an Orthotopic Model of Human Pleural Mesothelioma in Athymic Mice
Published on: December 21, 2019
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...