Related Experiment Video
Updated: Jan 24, 2026

Analysis of AtHIRD11 Intrinsic Disorder and Binding Towards Metal Ions by Capillary Gel Electrophoresis and Affinity Capillary Electrophoresis
Published on: August 22, 2018
Automated detection and removal of capillary electrophoresis artifacts due to spectral overlap
Jonathan D Adelman1, Angie Zhao1, D Spencer Eberst1
1Forensic & National Security Sciences Institute, Syracuse University, Syracuse, New York, USA.
Abstract:
While DNA detection using capillary electrophoresis has enabled improvements in both resolution and throughput, the use of CE - particularly with multiple dye channels - can introduce artifacts that can complicate analyses. Undetected pull-up artifacts can pose a challenge to investigators, especially in low-level samples, while partial pull-up peaks can distort peak height balance within a locus and impact the downstream likelihood ratio. Current methods for addressing pull-up are typically manually implemented. This study presents an effective alternative: a series of mathematical models, created using symbolic regression achieved through genetic programming. The models estimate the amount of pull-up expected in a peak from a true allele for a given dye-dye relationship and instrument type. This leads to the removal of artifactual pull-up peaks and peak height corrections when pull-up is present within true alleles. When models are used in conjunction with a dynamic threshold, pull-up peaks were automatically detected and removed with an accuracy rate of 96.1%. The removal of partial pull-up from true allele peaks led to a more accurate heterozygote balance for the affected locus. These models have been optimized for use with any analytical threshold and can be implemented by any lab using a 3100 or 3500 instrument series.
More Related Videos
14:12Amplification of Escherichia coli in a Continuous-Flow-PCR Microfluidic Chip and Its Detection with a Capillary Electrophoresis System
Published on: November 21, 2023
14:53Capillary Electrophoresis Separation of Monoclonal Antibody Isoforms Using a Neutral Capillary
Published on: January 16, 2017
Related Concept Videos
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
Capillary Beds
Capillaries connect arterioles, small branches of arteries, to venules,...
Capillary Exchange
Electrophoresis: Overview
There...