Related Experiment Video
Updated: Jan 24, 2026

Synthesis of Esters Via a Greener Steglich Esterification in Acetonitrile
Published on: October 30, 2018
Comparison assessment between SIM and MRM mode in the analysis of 3-MCPD ester, 2-MCPD ester and glycidyl ester
Kok Ming Goh1, Yu Hua Wong1, May Yen Ang2
1Department of Food Technology, Faculty of Food Science and Technology, Universiti Putra Malaysia, Serdang, Selangor 43400, Malaysia.
Abstract:
The detection of 3- and 2-MCPD ester and glycidyl ester was transformed from selected ion monitoring (SIM) mode to multiple reaction monitoring (MRM) mode by gas chromatography triple quadrupole spectrometry. The derivatization process was adapted from AOCS method Cd 29a-13. The results showed that the coefficient of determination (R2) of all detected compounds obtained from both detection mode was comparable, which falls between 0.997 and 0.999. The limit of detection and quantification (LOD and LOQ) were improved in MRM mode as compared to SIM mode. In MRM mode, the LOD of 3- and 2-MCPD ester was achieved 0.01 mg/kg while the LOQ was 0.05 mg/kg. Besides, LOD and LOQ of glycidyl ester were 0.024 and 0.06 mg/kg respectively. A blank spiked with MCPD esters (0.03, 0.10 and 0.50 mg/kg) and GE (0.06, 0.24 and 1.20 mg/kg) were chosen for repeatability and recovery tests. MRM mode showed better repeatability in area ratio and recovery with relative standard deviation (RSD %) < 5% for 2-, 3-MCPD ester at 0.5 mg/kg and GE at 1.2 mg/kg. Quantification of 22 food samples from different category were performed by repeated injections in both detection modes. Briefly, the contaminants from crude palm oil, mustard and olive oil were present in minute amount which below the LOD or LOQ in both detection modes. Sample from chocolate and infant formula products showed certain level of MCPD esters and GE, and their detection was more precisely quantitated based on MRM mode. Besides, margarine products showed a higher level of contaminations due to the high fat content in these products. MRM mode detection was proven to provide precise data with low RSD % in different food matrices. MRM mode detection was robust and selective for MCPD esters and GE analyses, it should be applied to determine the concentration of MCPD esters and GE contaminations in food.
More Related Videos
08:46Regioselective O-Glycosylation of Nucleosides via the Temporary 2',3'-Diol Protection by a Boronic Ester for the Synthesis of Disaccharide Nucleosides
Published on: July 26, 2018
06:00One-pot Microwave-assisted Conversion of Anomeric Nitrate-esters to Trichloroacetimidates
Published on: January 15, 2018
Related Concept Videos
Acid Halides to Esters: Alcoholysis
Esters to Alcohols: Hydride Reductions
Lithium aluminum hydride is a source of hydride ions and functions as a nucleophile. The mechanism proceeds in three steps. Firstly, the nucleophilic hydride ion attacks the carbonyl carbon of the ester to form a tetrahedral intermediate. Subsequently, the carbonyl group re-forms,...
Esters to Alcohols: Grignard Reaction
The reaction requires two equivalents of the Grignard reagent and introduces two identical alkyl groups, derived from the Grignard reagent, bonded to the hydroxyl-bearing carbon of the alcohol.
The reaction follows the typical nucleophilic acyl substitution mechanism. The Grignard...
Esters to Carboxylic Acids: Saponification
The reaction requires a base in stoichiometric amounts, which participates in the reaction and is not regenerated later. So, the base acts as a...
Esters to Carboxylic Acids: Acid-Catalyzed Hydrolysis
During hydrolysis, the ester is first activated towards nucleophilic attack through the protonation of the carboxyl oxygen atom by the acid catalyst. The protonation makes the ester carbonyl carbon more electrophilic. In the next step, water acts as a nucleophile and adds to the...
Esters to β-Ketoesters: Claisen Condensation Mechanism