Related Experiment Video
Updated: Jan 24, 2026

A Mouse Model of Retinal Ischemia-Reperfusion Injury Through Elevation of Intraocular Pressure
Published on: July 14, 2016
Central retinal venous pressure is higher than intraocular pressure during amateur trumpet playing
Egbert Matthé1, Marie-Caroline Schlief1, Sylvana Georgii1
1Department of Ophthalmology, University Hospital Carl Gustav Carus, TU Dresden, Augenklinik, Univ. Klinikum Carl Gustav Carus, Fetscherstrasse 74, 01307, Dresden, Germany.
Background:
It has been shown in the literature that the Valsalva manoeuvre influences ocular perfusion by changing intraocular pressure and central retinal venous pressure (CRVP). High-resistance wind instrument (HRWI) playing is a common situation resembling a Valsalva manoeuvre. The aim of this investigation was to explore the influence of amateur trumpet playing on CRVP.
Methods:
The left eyes of 20 healthy non-professional trumpet players (median age 26, range 19-52 years; 17 males, 3 females) were included in this investigation. Subjects, sitting at a slit lamp, were asked to play the tone b' flat with their own mouthpiece on the same trumpet for at least 30 s with moderate loudness. The following data were obtained: intraocular pressure (IOP) by applanation tonometry before and during playing, CRVP by contact lens dynamometry before and during playing, airway pressure (AirP) using a pressure sensor during playing and blood pressure and heart rate using the common cuff method before and during playing.
Results:
The results are presented as the medians before vs during playing: a calculated mean ophthalmic artery pressure of 66 vs 72 mmHg, heart rate of 76 vs 82 beats per minute, airway pressure of 0 vs 17 mmHg, IOP 12 vs 13 mmHg and CRVP of 24 vs 55 mmHg (Wilcoxon test: p = 0.00009), respectively. A correlation between the CRVP during playing and the height of the spontaneous CRVP is noted (Spearman rank correlation coefficient: ρ = 0.68).
Conclusions:
Amateur trumpet playing increases CRVP, airway pressure and IOP. The increase in CRVP is greater than that of the intraocular pressure. The increase in CRVP seems to be more important for retinal perfusion changes during trumpet playing than the increase of IOP. It can be hypothesised that high airway pressure during playing may cause a permanent increase in CRVP, at least in a subgroup of trumpet players.
More Related Videos
Related Concept Videos
Vapor Pressure
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Constant Pressure Calorimetry
Vapor Pressure Lowering
Osmosis and Osmotic Pressure of Solutions
Pressure Gauges

