Related Experiment Video
Updated: Jan 24, 2026

Capillary Electrophoresis Separation of Monoclonal Antibody Isoforms Using a Neutral Capillary
Published on: January 16, 2017
Analyte focusing by micelle collapse for liquid extraction surface analysis coupled with capillary electrophoresis of
Sunkyung Jeong1, Farid Shakerian1, Doo Soo Chung1
1Department of Chemistry, Seoul National University, Seoul, South Korea.
Abstract:
Liquid extraction surface analysis (LESA) has an advantage of directly sampling analytes on a surface, thus avoiding unnecessary dilution by homogenization of the bulk sample commonly practiced in solid sample analysis. By combining LESA with CE, the additional advantage of separating analytes before detection can be accomplished. For neutral molecules, MEKC needs to be used. Since the detection sensitivity of CE in general suffers from the small capillary dimension, analyte focusing by micelle collapse was employed for enhanced extraction in LESA and sample preconcentration for MEKC. In addition, using a commercial CE instrument, the LESA process was performed much faster and more reliably compared to our first demonstration of LESA-CE using a homemade CE setup. Three neutral water-insoluble pesticides sprayed on an apple skin were directly extracted, preconcentrated, and analyzed by the automated LESA-analyte focusing by micelle collapse-MEKC with high sensitivity in 10 min. The relative standard deviations of the migration times and peak heights were 0.8-2.1 and 1.2-3.0%, respectively when ametryn was used as an internal standard. The limits of detection obtained with UV absorbance at 200 nm were 1.8-6.4 ppb.
Related Concept Videos
Surface Tension, Capillary Action, and Viscosity
The various IMFs between identical molecules of a substance are examples of cohesive forces. The molecules within a liquid are surrounded by other molecules and are attracted equally in all directions by the cohesive forces within the liquid. However, the molecules on the surface of a liquid are attracted only by about one-half as many molecules. Because of the unbalanced molecular attractions on the surface molecules, liquids contract to form a shape that minimizes the number...
Bending of Curved Members - Neutral Surface
Consider the curved member described in the previous lesson. According to Hooke's law, which relates stress to strain within the...
Development of Analytical Methods
Analyte Adsorption and Distribution
Jung's Analytical Theory
Graphical and Analytic Representation of Sinusoids
The first step is measuring the peak-to-peak value, which is twice the amplitude of the sinusoid. This provides information about the maximum voltage swing of the waveform.
Secondly, the period and angular frequency are determined. The period is the time taken for one complete cycle of the waveform, while...

