Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Three-dimensional extent of flow stagnation in transcatheter heart valves
Vrishank Raghav1, Chris Clifford1, Prem Midha2,3
11 Auburn University , Auburn, AL 36849 , USA.
Abstract:
The recent unexpected discovery of thrombosis in transcatheter heart valves (THVs) has led to increased concerns of long-term valve durability. Based on the clinical evidence combined with Virchow's triad, the primary hypothesis is that low-velocity blood flow around the valve could be a primary cause for thrombosis. However, due to limited optical access in such unsteady three-dimensional biomedical flows, measurements are challenging. In this study, for the first time, we employ a novel single camera volumetric velocimetry technique to investigate unsteady three-dimensional cardiovascular flows. Validation of the novel volumetric velocimetry technique with standard planar particle image velocimetry (PIV) technique demonstrated the feasibility of adopting this new technique to investigate biomedical flows. This technique was used to quantify the three-dimensional velocity field in the vicinity of a validated, custom developed, transparent THV in a bench-top pulsatile flow loop. Large volumetric regions of flow stagnation were observed in the neo-sinus throughout the cardiac cycle, with stagnation defined as a velocity magnitude lower than 0.05 m s-1. The volumetric scalar viscous shear stress quantified via the three-dimensional shear stress tensor was within the range of low shear-inducing thrombosis observed in the literature. Such high-fidelity volumetric quantitative data and novel imaging techniques used to obtain it will enable fundamental investigation of heart valve thrombosis in addition to providing a reliable and robust database for validation of computational tools.
More Related Videos
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Anatomy of the Heart
Static, Stagnation, Dynamic and Total Pressure
Dimensional Analysis
Conversion Factors and Dimensional Analysis
The unit...
Mitral Valve Prolapse I: Introduction
Mitral Valve Prolapse II: Assessment and Management