Cine balanced fast field echo magnetic resonance imaging of canine spinal arachnoid diverticulae pulsation
Related Experiment Video
Updated: Jan 24, 2026

3D Cine Magnetic Resonance Imaging of Respiratory Motion in Mechanically Ventilated Mice and Rats
Published on: September 19, 2025
S K Shivapour1, H A Volk1, V Watts1
1Department of Veterinary Clinical Science and Services, Royal Veterinary College, University of London, Hawkshead Lane, North Mymms, Hertfordshire AL97TA, UK.
Abstract:
Canine spinal arachnoid diverticulae (SAD) are characterised by focal cerebrospinal fluid dilatations within the subarachnoid space, most commonly associated with nonpainful paresis and ataxia secondary to chronic compressive myelopathy. Numerous imaging techniques have been described for diagnosis of this condition, including myelography, computed tomography myelography, and magnetic resonance imaging (MRI). The present retrospective study investigated the utility of cine balanced fast field echo (cine bFFE) MRI sequences in measuring pulsatile flow in 12 dogs with SAD. The secondary aim was to determine the prevalence and location of syringes in relation to SAD, as the co-occurrence of these conditions has not been previously reported. The degree of SAD pulsation was calculated as the change in area per cardiac cycle on sagittal (n = 12/12) and transverse (n = 7/12) cardiac-gated cine bFFE MRI sequences. Pulsation was identified on all sequences, with a median ratio of change in SAD area of 0.14 (range, 0.10-0.27; n = 12) on sagittal cine bFFE and 0.23 (range, 0.05-0.53; n = 7) on transverse cine bFFE sequences. Significant differences between minimum and maximum SAD dimensions were identified on sagittal (P = 0.002) and transverse measurements (P = 0.018). A moderate prevalence of syringomyelia was identified (n = 6/12; 50%) on T2W sequences, occurring both cranial (n = 4/12; 33%) and caudal (n = 2/12; 17%) to the SAD. These results support the ability of cine bFFE sequences to identify dynamic pulsation of canine SAD. This technique is currently limited by banding artifacts and its inability to quantify flow velocity and abnormal flow jets.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
Magnetic Fields
A magnetic field is defined by the force that a charged particle experiences...
Echo
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
Magnetic Field of a Solenoid
Consider a solenoid with 100 turns wrapped around a cylinder of...
Magnetic Field Lines
Magnetic field lines follow several hard-and-fast rules: